图片名称

Exhibition Invitation | Lixun Testing cordially invites you to attend the 7th Thermal Management Industry Conference and Expo (iTherM2026) in 2026

Author.

LCS

Source:

Post time:

2026-11-11

The 7th Thermal Management Industry Conference and Expo 2026 (iTherM2026)

Lixun Testing cordially invites you

Join the grand event and seek common development

 

 

Exhibition Information

 

Exhibition time: December 2-4, 2026

 

Exhibition location: Shenzhen International Convention and Exhibition Center (Bao'an)

 

Booth Number: E46

 

Long press the image above to recognize the QR code

Get free admission tickets

 

Exhibition Introduction

 

 

The conference gathers over 350 exhibitors, with an exhibition area of approximately 20000 square meters and an expected attendance of over 28000 professional visitors. More than 20 special presentations, roundtable discussions, roadshows, and promotional activities will be arranged.

 

Main exhibition areas

Thermal management materials: thermal conductive gasket, thermal conductive gel, graphite film, ceramic substrate, diamond heat sink, aerogel, etc

Thermal management components: heat pipe, VC heat sharing plate, liquid cooling plate, fan, radiator, pump valve, etc

Liquid cooling and temperature control systems: immersion liquid cooling, cold plate liquid cooling, precision air conditioning, heat exchange equipment

Terminal solutions: consumer electronics, data center/AI computing power, new energy vehicles, energy storage, semiconductors, charging stations

Automation equipment and testing instruments: coating, die-cutting, sintering, thermal simulation, thermal imaging, thermal analysis instruments, etc

 

 

 

 

Our Services

 

Lixun Testing Group was established in 2004 and has been committed to providing one-stop product testing and certification services for many years. Its business covers electromagnetic compatibility, wireless radio frequency, product safety, new energy batteries, thermal management, energy efficiency performance, lighting fixtures, automotive electronics, environmental reliability, ecological environment testing, and chemistry. The company has established more than 40 large-scale testing laboratories, providing services related to various domestic and international testing and certification projects such as FCC certification, CE certification, CB certification, REACH certification, RoHS certification, PSE certification, SAA certification, TELEC certification, etc.

 

 

(1) Pulse test bench

Computer control mode, hydraulic servo system

Pressure range: -50-2000KPa

Frequency: 0-3Hz, involving negative pressure pulse frequency<0.5Hz, the test frequency is inversely proportional to the volume of the specimen

Environmental temperature: -40~180 ℃, can be freely selected

Medium temperature: -40~150 ℃, can be freely selected

Heating and cooling rate, 0~5 ℃/min can be freely selected, average throughout the process, with a mass load of 30kg/sample, a total of 90KG aluminum, no heating

Test medium: water, ethylene glycol, refrigerant

Medium flow rate: 5~50L/min, total circuit control

Pulse waveform: sine wave (0~3Hz), triangular wave (0~3Hz), trapezoidal wave (0~1Hz), square wave (boost time not less than 150ms, 0~0.5Hz)

Environment box size: 2.8 * 2 * 1m (5.6m ³), double door

Workstation: 3

 

(2) Vacuum test bench/blasting test bench/airtight test bench comprehensive test bench

Vacuum test: pressure: 0-100KPa

Vacuum pumping rate: 10~60Kpa/min

Blasting test: computer-controlled method, gas-liquid pump pressurization method

Test pressure: 0.1-30MPa

Test medium: water, ethylene glycol, refrigerant, at room temperature

Boosting rate: 5-200bar/min

Air tightness test: computer-controlled mode

Test medium: Compressed air, 0.1-0.5 MPa

Medium temperature: normal temperature, uncontrolled temperature

Leakage determination requirements: pressure drop, leakage volume, bubble method (equipped with leak detector, only used for dry inspection)

Test box size: 2.8 * 2 * 1m (sink size: 2.6 * 1.8 * 0.4m)

 

(3) Cold and hot cycle test bench

Computer control mode

Test medium: water, ethylene glycol, refrigerant

High temperature tank temperature: RT+10~130 ℃

Low temperature tank temperature: -40~30 ℃

Impact frequency: Max15 times/h (with three liquid cooled plates)

to attack:

Quick switching, switching time ≤ 20s

Slow rate control, temperature rate: ≤ 15 ℃/min, average throughout the entire process, with a mass load of 30kg/

Impact total flow rate: 12~120L/min total flow monitoring, three independent controllable channels 4~40L/min;

Pressure: 0-4Bar, controlled at different pressure and flow rates (not controlled during conversion, controlled during steady state)

Room temperature test room: 2.8 * 2 * 1m

Workstation: 3

 

(4) Internal corrosion test bench

Computer control mode

Test medium: water, ethylene glycol, refrigerant

Temperature: RT+20~125 ℃, three independent temperatures, independent flow rate;

Heating rate: 1-2 ℃/min

Flow range: Three channels, each channel 10-100L/min, flow sensor accuracy ± 1% F.S

Pressure range: 0.5~3Bar, can control different pressures and flow rates.

Environmental temperature: normal temperature

Internal dimensions: 2.8 * 2 * 1m

Workstation: 3

 

(5) Flow resistance test bench

Test medium: water, ethylene glycol, refrigerant

Medium temperature: -40~120 ℃

Flow range: 0.2~40L/min, domestic flow scoring in two stages, range 1: 0.2-2L/min accuracy ± 0.15% f.s, range 2: 2-40L/min; 4-40L/min accuracy ± 0.15% f.s; 2-4 L/min accuracy ± 0.5% f.s,

Measurement pressure difference range: 0.05~100KPa, accuracy ± 0.1% FS;

Environmental temperature: normal temperature

Test piece testing station: single station, external test piece station, supported by an external steel frame, equipped with a residual liquid collection tray at the bottom (configured according to the maximum size of the test piece: 2.8 × 2m). When the product is subjected to temperature control and flow resistance, it needs to be insulated and wrapped to prevent heat loss.

 

(6) Nitrogen testing

Internal volume of workpiece: ≤ 10L

Helium filling pressure: 5MPA, adjustable downwards

Leakage rate: 2 grams per year

Paired with positive and negative pressure modes

Media Center

Latest News

Contact Us

图片名称
图片名称

National 24-hour service hotline

400-116-2629

Group Headquarters

Cell phone:18126505465

E-mail: webmaster@lcs-cert.com

Address: Shenzhen City, Baoan District, Shajing Street, Nga side of the school of Wei Juji Industrial Park, Building A 1 ~ 2 floor, Building C 3 floor