Portable transmitter anti-interference

Assess the potential risks of DUT exposure to radiation from handheld portable transmitters (such as mobile phones), with a testing frequency range of 26~6000MHz. This test is only applicable to specific devices installed in the passenger compartment or luggage compartment.

 

Test purpose

Evaluate the anti-interference performance of electronic devices in the radiation environment of portable transmitters.

Ensure that the device can function properly under the radiation of the portable transmitter.

Identify potential failure risks of devices in the radiation environment of portable transmitters.

 

Test Principle

The portable transmitter immunity test simulates the radiation field strength of a handheld portable transmitter (such as a mobile phone), applies a specific frequency and intensity of electromagnetic field to the device under test (DUT), and observes whether the device experiences performance degradation or malfunction.

 

test frequency

Typical frequency range: 26 MHz~6000 MHz.

Focus on frequency bands:

26 MHz~1 GHz: Low frequency band, mainly from traditional communication devices such as walkie talkies.

1 GHz~6 GHz: High frequency band, mainly from modern communication devices such as mobile phones and Wi Fi.

 

test equipment

Signal generator:

Used to generate interference signals of specific frequency and intensity.

Power amplifier:

Used to amplify the output signal of the signal generator.

Transmitting antenna:

Used to generate electromagnetic fields and simulate the radiation of portable transmitters.

Field strength probe:

Used to measure electromagnetic field strength and ensure the accuracy of testing conditions.

Receiver or spectrum analyzer:

Used to monitor the frequency and intensity of interference signals.

Control software:

Used to set test parameters such as frequency, intensity, and duration.

Shielding room or test bench:

Provide a testing environment without external interference.

 

Test steps

Preparation:

Install the device under test (DUT) on the test bench and connect all necessary cables and power sources.

Ensure that the equipment is in normal working condition.

Set up testing environment:

Install signal generators, power amplifiers, transmitting antennas, and field strength probes in shielded rooms or test benches.

Calibrate the transmitting antenna to ensure that the electromagnetic field strength meets the testing requirements.

Conduct testing:

Start the tested device and put it in typical working mode.

Use a signal generator and power amplifier to generate interference signals of specific frequency and intensity.

Apply an electromagnetic field to the device under test through a transmitting antenna.

Observe the performance changes of the equipment and record any abnormalities or malfunctions.

data analysis

Analyze test data and evaluate the anti-interference performance of the equipment.

Determine whether the equipment is qualified according to the standard limit.

 

Test Standard

ISO 11452-9: Road vehicles - Test methods for narrowband radiated electromagnetic energy immunity - Part 9: Portable transmitter immunity test.

SAE J1113-27: Electromagnetic Compatibility Testing of Automotive Electronic Devices - Portable Transmitter Immunity Test.

 

test conditions

Field strength: usually 3 V/m~30 V/m, the specific strength depends on the testing standards and application scenarios.

Test frequency: 26 MHz~6000 MHz.

Testing time: Each frequency point lasts for several seconds to minutes, depending on the testing standards.

 

Precautions

Test environment: Ensure that there is no external interference in the shielded room or test bench.

Equipment status: Ensure that the tested equipment is in a typical working state, covering all possible working modes.

Antenna calibration: Regularly calibrate the transmitting antenna and field strength probe to ensure the accuracy of testing conditions.

Safety protection: During the testing process, attention should be paid to the potential impact of high-frequency electromagnetic fields on the human body and necessary protective measures should be taken.

 

Common problems and solutions

Equipment performance degradation:

Reason: Unreasonable circuit design, insufficient shielding, inadequate filtering, etc.

Solution: Optimize circuit design, add shielding measures, and use filters.

The test results are unstable:

Reason: External interference, unstable device operation status.

Solution: Test in a shielded environment to ensure consistent device operation.

 

Application field

Automotive electronics: in car entertainment systems, navigation systems, sensors, etc.

Consumer electronics: smart devices, household appliances, etc.

Industrial electronics: industrial controllers, motor drivers, etc.

 

Conclusion

Portable transmitter immunity testing is an important means of evaluating the immunity performance of electronic devices in the radiation environment of portable transmitters. By simulating electromagnetic interference in actual environments, potential risks of equipment in actual working environments can be identified and necessary improvement measures can be taken. During the testing process, attention should be paid to the testing environment, equipment status, and antenna calibration to ensure the accuracy and reliability of the test results.

6 individual

Large-scale experimental base

150 individual

Professional Lab

30 All kinds of

Analysis Method

8 million times

Testing/year