Electrostatic Discharge

Assess the resistance of the equipment to direct discharge or electrostatic field interference generated by external static power sources (such as charged human bodies, charged equipment, etc.), with test levels of 4KV for contact discharge and 8KV for air discharge.

 

Electrostatic Discharge (ESD) testing is an important component of Electromagnetic Compatibility (EMC) testing, used to evaluate the anti-interference performance of Equipment Under Test (EUT) under direct discharge or electrostatic field interference from external static power sources (such as charged human bodies, charged equipment, etc.). The electrostatic discharge test simulates the electrostatic interference that the equipment may encounter in actual usage environments, ensuring that the equipment can still function normally under electrostatic discharge conditions.

 

Test purpose
The main purpose of electrostatic discharge testing is to verify whether the equipment can maintain normal function without performance degradation, misoperation, or damage when subjected to electrostatic discharge interference. This is crucial for ensuring the reliability and safety of equipment, especially in fields such as consumer electronics, industrial control, medical equipment, and automotive electronics.

 

Test Standard
Electrostatic discharge testing is usually conducted according to international or industry standards, and common standards include:

IEC 61000-4-2: Standard for electrostatic discharge immunity testing developed by the International Electrotechnical Commission (IEC).

EN 61000-4-2: European standard, consistent with the content of IEC 61000-4-2.

GB/T 17626.2: Chinese National Standard, equivalent to IEC 61000-4-2.

 

test method
Test environment:

Testing is typically conducted in a laboratory environment using a specialized electrostatic discharge simulator.

The testing environment should control humidity and temperature (usually 30% -60% humidity and 15 ℃ -35 ℃ temperature) to ensure the accuracy of the test results.

Test equipment:

Electrostatic discharge simulator: used to generate electrostatic discharge that meets standard requirements.

Ground reference plane (GRP): used to simulate the grounding conditions of equipment in actual use.

Monitoring equipment: used to monitor the working status and performance of the tested equipment.

Test steps:

Place the test equipment on the grounding reference plane and connect the necessary power and signal lines.

Set the parameters of the electrostatic discharge simulator according to the testing standards:

Contact discharge: The test level is usually 4 kV (adjustable according to standards or product requirements).

Air discharge: The test level is usually 8 kV (adjustable according to standards or product requirements).

Perform electrostatic discharge testing on parts that may come into contact with the device's casing, buttons, interfaces, etc.:

Contact discharge: Directly contact the discharge gun with the surface of the equipment for discharge.

Air discharge: Place the discharge gun close to the surface of the equipment and discharge through an air gap.

Apply multiple discharges (usually 10 positive and 10 negative) at each testing point, and observe whether the tested equipment shows performance degradation, misoperation, or damage.

Record the test results, including the response of the tested equipment and any abnormal phenomena.

Test parameters:

Contact discharge: 4 kV (typical value, adjustable according to standards or product requirements).

Air discharge: 8 kV (typical value, adjustable according to standards or product requirements).

Discharge frequency: Each test point usually has 10 positive and 10 negative polarity discharges.

Discharge interval: Each discharge interval should be at least 1 second to ensure that the equipment has sufficient time to recover.

 

Test result evaluation
According to the standard, the tested equipment should maintain normal operation during the testing process without significant performance degradation or functional failure.

Failure criteria: If the device experiences performance degradation, misoperation, or damage during testing, it will be considered a test failure.

Rectification measures: For devices that have not passed the test, the following measures may need to be taken:

Add electrostatic protection devices (such as TVS diodes, ESD suppressors, etc.).

Optimize the design of the equipment casing and add grounding measures.

Improve circuit design and enhance anti-static capability.

 

Application field
Electrostatic discharge testing is widely used in the following fields:

Consumer electronics: such as mobile phones, computers, household appliances, etc.

Industrial equipment: such as PLC, frequency converter, industrial robots, etc.

Medical equipment: such as electrocardiographs, ultrasound devices, etc.

Automotive electronics: such as in car entertainment systems, autonomous driving sensors, etc.

Communication equipment: such as base stations, routers, etc.

 

Test significance
Through electrostatic discharge testing, it can be ensured that the equipment can operate stably even in actual use environments when subjected to electrostatic interference, meeting regulatory requirements and improving user satisfaction. This is of great significance for ensuring the reliability and safety of equipment in static sensitive environments, especially in dry or static prone environments.