burning test

After fully charging the battery according to the test method specified in 4.5.1, place the battery on the steel wire mesh of the test fixture. The test fixture is attached
Record the C.2 of C. If the battery slips during the experiment, a single metal wire can be used to fix the battery sample on the steel wire mesh; as
If no such situation occurs, the battery cannot be bundled. Heat the battery with a flame and stop heating when the following three situations occur:
a) Battery explosion;
b) The battery is completely burned;
c) Continuous heating for 30 minutes, but the battery did not catch fire or explode.
After the experiment, the components that make up the battery (excluding dust like products) or the entire battery should not penetrate the aluminum mesh.

 

Combustion testing is an important testing method for evaluating the safety and flame resistance of batteries under extreme high temperature or open flame conditions. By simulating the reaction of batteries in fire or high temperature environments, detect whether the battery will explode, catch fire, or penetrate aluminum mesh and other dangerous situations. The following is the detailed content of the combustion test:

 

1. Test purpose

Evaluate the safety and flame resistance of batteries under open flame or high temperature conditions.

Ensure that the battery does not explode, catch fire, or penetrate aluminum mesh under extreme conditions.

Verify whether the battery meets relevant safety standards and requirements.

 

2. Testing principle

By placing the battery on a steel wire mesh and heating it directly with a flame, observe the reaction of the battery under high temperature or open flame conditions, and detect whether it will explode, catch fire, or penetrate the aluminum mesh.

 

3. Testing methods

(1) Test preparation

Fully charge the battery according to standard methods.

Prepare steel wire mesh and flame heating equipment (such as propane spray lamps).

Prepare aluminum mesh for detecting whether the battery penetrates after combustion.

(2) Combustion test

Place the battery on the wire mesh of the test fixture.

If the battery slips during the testing process, a single metal wire can be used to secure the battery.

If the battery has not slipped off, do not bundle the battery.

Heat the battery with a flame and observe its reaction.

Stop heating when one of the following three situations occurs:
a) Battery explosion;
b) The battery is completely burned;
c) Continuous heating for 30 minutes, but the battery did not catch fire or explode.

Record the reaction of the battery (such as ignition time, explosion time, combustion duration, etc.).

(3) Check after testing

Check if the residue after battery combustion has penetrated the aluminum mesh.

Observe whether there are any dangerous situations such as explosion or fire in the battery.

Record the state of the battery after combustion (such as whether it is completely burned, whether there are residues, etc.).

 

4. Testing standards

International standards:

IEC 62133 (Safety requirements for portable sealed secondary batteries).

UN 38.3 (Safety testing for transportation of lithium batteries).

Industry standards:

GB 31241 (Safety Requirements for Lithium ion Batteries for Portable Electronic Products, China).

UL 1642 (Lithium Battery Safety Standard, USA).

 

5. Testing equipment

Wire mesh: used for placing batteries.

Flame heating equipment: such as propane spray lamps, used to heat batteries.

Aluminum mesh: used to detect whether the battery penetrates after combustion.

Infrared thermal imaging device: used to monitor temperature changes during battery combustion process.

 

6. Data analysis and evaluation

Combustion reaction: Record whether the battery has exploded, caught fire, or completely burned.

Penetration detection: Check whether the residue after battery combustion penetrates the aluminum mesh.

Safety assessment: Evaluate the safety performance of batteries during combustion testing.

 

7. Common problems and solutions

Battery explosion: It may be due to excessive internal pressure or material failure of the battery, and battery design and production processes need to be optimized.

Battery fire: It may be due to the flammable electrolyte or severe reaction of electrode materials, and the electrolyte or electrode materials need to be improved.

Penetrating aluminum mesh: It may be due to excessive residual energy after battery combustion, and the battery structure and materials need to be optimized.

 

8. Application scenarios

Battery testing for consumer electronics products such as mobile phones, laptops, and tablets.

Electric tools: such as battery testing for electric drills and chainsaws.

Electric vehicles: such as testing of electric vehicle power batteries.

Energy storage system: such as testing of solar energy storage batteries.

 

9. Test report

Test conditions: including flame heating method, heating time, testing environment, etc.

Test results: including combustion reaction, penetration detection, safety assessment, etc.

Conclusion and Suggestions: Evaluate whether the sample meets the relevant standards and propose improvement suggestions.

Through combustion testing, the safety and flame resistance of batteries under extreme high temperature or open flame conditions can be comprehensively evaluated, ensuring that they can meet safety requirements in practical use and providing scientific basis for battery design and optimization.

6 individual

Large-scale experimental base

150 individual

Professional Lab

30 All kinds of

Analysis Method

8 million times

Testing/year