Classification of electrical energy sources

The ES PS RS TS MS of the equipment is classified into levels 1, 2, and 3, and different protection levels are required for different populations.

The classification of electric energy sources is based on the level of energy that the equipment may release, dividing it into different levels (such as level 1, level 2, level 3), and developing corresponding protection requirements for different groups of people (such as ordinary users, professionals, and trained personnel). The following is a detailed explanation of the classification of electric energy sources:

 

The purpose of grading electric energy sources

The main purpose of grading electric energy sources is to:

Risk assessment: Assess the potential risks to personnel and the environment based on the energy level that the equipment may release.

Develop protective measures: Develop corresponding protective requirements for different levels of electrical energy sources to ensure the safety of personnel and equipment.

Standardized design: Provide guidance for equipment design to ensure compliance with safety standards.

 

Classification of Electric Energy Sources

Electric energy sources are usually classified into the following levels based on their energy levels:

Level 1:

The energy level is low and usually does not cause harm to personnel.

Suitable for ordinary users, no special protective measures are required.

For example, low-power electronic devices such as mobile phone chargers and small household appliances.

Level 2:

Moderate energy level, may cause minor injury to personnel.

Suitable for professionals or trained personnel, basic protective measures must be taken.

For example, medium power equipment such as industrial controllers and power tools.

Level 3:

High energy levels may cause serious injury to personnel.

Only applicable to professionals, strict protective measures must be taken.

For example: high-power equipment (such as high-voltage power supplies, large industrial equipment).

 

Protection level requirements

The protection requirements for different levels of electric energy sources and different populations are as follows:

Level of electric energy sourceApplicable Populationprotection requirements
Level 1regular userNo special protective measures are required, and the equipment design should comply with basic safety standards.
Level 2Professional or trained personnelBasic protective measures need to be taken, such as warning signs, safety operation training, etc.
Level 3professionalStrict protective measures must be taken, such as isolation devices, protective equipment, safety operating procedures, etc.

 

Type of electric energy source

The classification of electric energy sources usually involves the following types:

ES(Energy Source):

The energy source of the device, such as batteries, power sources, etc.

PS(Power Source):

The power supply part of the equipment, such as transformers, inverters, etc.

RS(Risk Source):

Dangerous parts in the equipment, such as high-voltage circuits, rotating components, etc.

TS(Thermal Source):

Parts of the equipment that may generate high temperatures, such as radiators and heating elements.

MS(Mechanical Source):

The parts of the equipment that may pose mechanical hazards, such as moving parts, cutting devices, etc.

 

relevant standards

The criteria for grading electric energy sources vary depending on the industry and product type. Common standards include:

IEC 62368-1: Safety requirements for audio, video, information and communication technology equipment.

IEC 60950-1: Safety requirements for information technology equipment.

IEC 60601-1: Safety requirements for medical electrical equipment.

UL 62368-1: American standard, similar to IEC 62368-1.

 

Grading process

Determine the type of energy source:

Identify the type of energy source in the device (such as ES, PS, RS, etc.).

Evaluate energy level:

Measure or calculate the energy level of an energy source (such as voltage, current, power, etc.).

Classification level:

Divide energy sources into level 1, level 2, or level 3 based on their energy levels.

Develop protective measures:

Develop corresponding protective measures for different levels of energy sources and applicable populations.

Verification and testing:

Verify the effectiveness of protective measures through testing to ensure that the equipment meets safety standards.

 

Application field

The classification of electric energy sources is widely used in the following fields:

Electronic and electrical equipment: such as power supplies, transformers, motors, etc.

Household appliances: such as refrigerators, washing machines, air conditioners, etc.

Industrial equipment: such as frequency converters PLC、 Industrial controllers, etc.

Medical equipment: such as medical instruments, diagnostic equipment, etc.

By classifying electric energy sources, the safety risks of equipment can be comprehensively evaluated, corresponding protective measures can be formulated to ensure the safety of personnel and equipment, and important basis can be provided for product design, quality control, and market access.

6 individual

Large-scale experimental base

150 individual

Professional Lab

30 All kinds of

Analysis Method

8 million times

Testing/year