Common issues with high and low temperature testing

1、 Product Usage:

This product is suitable for safety and reliability testing of electronic components, product screening testing, etc. Through this equipment test, the reliability of the product can be improved and the quality control of the product can be carried out.

 

2、 Product Structure:

Imported European and American compressors with environmentally friendly refrigerants, plate heat exchangers, and binary ultra-low temperature refrigeration systems have RS-232 or RS-485 communication interfaces and connecting software, which can be remotely controlled by a computer for convenient use.

Two box type: the upper part is a high-temperature box and the lower part is a low-temperature box. The two boxes are connected by a sample rack and move between them through a transmission mechanism.

 

3、 The product meets the standards:

The equipment complies with high and low temperature impact tests such as GB/T2423.1.2, GB/T10592-2008, GJB150.3CNSMILIECJIS.

There may be various issues with the use, maintenance, and performance of high and low temperature test chambers, which can affect the accuracy of test results and shorten equipment lifespan. The following summarizes common problems and their causes from four dimensions: equipment itself, operation, testing process, and maintenance:

1、 Performance and malfunction issues of the equipment itself
Insufficient temperature control accuracy or large fluctuations: The deviation between the actual temperature and the set temperature exceeds the allowable range (such as ± 1 ℃ or more), or the temperature fluctuates frequently. Reason: Aging of temperature control sensor, malfunction of heating/cooling system (such as power attenuation of heater, lack of fluorine in compressor), uneven airflow circulation inside the box (fan failure).

Slow cooling/heating rate or inability to reach target temperature performance: Low temperature cannot be lowered below -40 ℃, high temperature cannot reach above 150 ℃, or the heating and cooling rate is far below the nominal value of the equipment. Reason: Excessive compressor load, refrigerant leakage, damaged heating tube, aging insulation layer (heat/cold leakage).

Abnormal humidity control (for high and low temperature humidity test chambers): high/low humidity, large humidity fluctuations, or inability to humidify/dehumidify. Reason: Humidifier malfunction (such as electrode scaling, water level sensor failure), dehumidification system (such as evaporator) blockage, humidity sensor calibration failure.

Poor sealing performance of the box: temperature leakage in the gaps of the box door, severe frosting/fogging of the observation window, resulting in unstable temperature inside the box. Reason: The aging and damage of the sealing strip, as well as the looseness of the box door hinges, resulted in poor closure.

Control system malfunction symptoms: unresponsive touch screen, interrupted program operation, and inability to save parameter settings. Reason: BUG in control system software, poor circuit contact, damage to motherboard or relay.

 

2、 Common problems in usage and operation
Improper placement of test samples affects the results: The samples are stacked too densely, close to sensors or air vents, resulting in uneven heating/cooling of the samples and distortion of test data. Essence: Failure to follow the placement specifications of "reserving sufficient space between samples and box walls, and between samples".

The problem of test load exceeding the equipment's carrying range: the volume and weight of the sample placed inside are too large, or the sample itself heats up (such as electronic components), causing the temperature inside the box to be difficult to stabilize. Risk: Long term overloading may burn out the heating/cooling system and even cause equipment overload protection shutdown.

Program setting error issue: Failure to set appropriate temperature change rate and cycle times according to testing standards (such as GB/T 2423), or ignoring the "preheating/pre cooling" step, resulting in the testing process not meeting specifications.

 

3、 Abnormal phenomena during the testing process
When there is excessive frosting/condensation inside the box during low-temperature testing, if the sample contains moisture or the box door is frequently opened, it will cause frosting on the evaporator, affecting the refrigeration efficiency; When switching between high temperature and high humidity, condensation water may adhere to the sample and interfere with the test.

Sample "frostbite" or "overheating damage" may be misdiagnosed as equipment failure due to physical/chemical changes occurring at temperature (such as plastic cracking, metal corrosion) caused by untreated samples (such as sealed and moisture-proof), in addition to equipment temperature control issues.

The poor repeatability of test data and the large deviation in test results for the same batch of samples may be due to insufficient uniformity of the equipment temperature field (temperature difference exceeding ± 2 ℃ at different positions inside the box), expired sensor calibration, or inconsistent operating procedures (such as different sample placement positions each time).

 

4、 Problems caused by improper maintenance and upkeep
Filter blockage leads to a decrease in cooling/heating efficiency. The air filter is not cleaned for a long time, and dust clogs the air duct, affecting the circulation of airflow inside the box; The blockage of the drying filter in the refrigeration system can cause poor refrigerant circulation and a sudden drop in cooling capacity.

Insufficient lubrication or aging of moving parts such as compressors and fans may cause abnormal noise or even jamming due to lack of oil; Failure to replace the aging sealing strips and pipeline interfaces in a timely manner may result in refrigerant leakage and box door temperature leakage.

 

Failure to regularly power on and operate equipment that has been idle for a long time may cause the compressor lubricating oil to solidify, the circuit to become damp and short circuited, resulting in the inability to cool/heat when restarted.

The core impact of these issues is the decrease in reliability of test results and the shortening of equipment life. The solution needs to be combined with regular calibration (such as annual calibration of temperature sensors and temperature field uniformity), standardized operating procedures (such as sample pretreatment and load control), and timely maintenance (cleaning filters, replacing vulnerable parts). The stability and troubleshooting ability of equipment are particularly critical for high-precision testing needs in different industries such as electronics, automotive, and aerospace.