Fluorescent lamp performance testing

IEC 60969; GB/T 17263 Performance Testing of Self ballasted Fluorescent Lamps

Fluorescent lamp performance testing is an important testing method for evaluating the performance of self ballasted fluorescent lamps (such as energy-saving lamps), mainly based on IEC 60969 and GB/T 17263 standards. The following is a detailed explanation about the performance testing of fluorescent lamps:

 

1. Overview of Testing Standards

(1) IEC 60969

Full name: IEC 60969《Self-ballasted lamps for general lighting services - Performance requirements》。

Scope of application: Suitable for performance testing of self ballasted fluorescent lamps (such as energy-saving lamps).

Main content: including performance indicators such as luminous flux, luminous efficiency, color temperature, color rendering index, start-up time, and lifespan.

(2) GB/T 17263

Full name: GB/T 17263 "Performance Requirements for Self ballasted Fluorescent Lamps for General Lighting".

Scope of application: Suitable for performance testing of self ballasted fluorescent lamps in the Chinese market.

Main content: Similar to IEC 60969, including performance indicators such as luminous flux, luminous efficiency, color temperature, color rendering index, start-up time, and lifespan.

 

2. Main testing items

(1) Luminous flux

Definition: The total amount of light emitted by a light source, measured in lumens (lm).

Test method: Use an integrating sphere and a photometer to measure the luminous flux of the light source.

(2) Light effect

Definition: The ratio of the luminous flux of a light source to the input power, measured in lumens per watt (lm/W).

Testing method: Measure the luminous flux and input power of the light source, and calculate the luminous efficiency.

(3) Color temperature

Definition: The color characteristic of light emitted by a light source, measured in Kelvin (K).

Test method: Use a colorimeter to measure the color temperature of the light source.

(4) Color rendering index (CRI)

Definition: An indicator of the ability of a light source to reproduce the color of an object, ranging from 0 to 100.

Testing method: Use a spectral radiometer to measure the spectral distribution of the light source and calculate the color rendering index.

(5) Start time

Definition: The time required from power on to 98% stable light output.

Test method: Use a photometer and timer to measure the start time.

(6) Lifespan

Definition: The time it takes for a light source to fail under rated conditions.

Testing method: Evaluate the lifespan of the light source through accelerated lifespan testing or actual lifespan testing.

(7) Power factor

Definition: The ratio of active power to apparent power of a light source.

Test method: Use a power analyzer to measure the power factor of the light source.

(8) Harmonic distortion

Definition: The proportion of harmonic components in the input current of a light source.

Test method: Use a harmonic analyzer to measure the harmonic distortion of the light source.

 

3. Testing equipment

Integral sphere: used for measuring luminous flux and luminous efficiency.

Photometer: used to measure light output.

Colorimeter: used to measure color temperature and color rendering index.

Power analyzer: used to measure power factor and harmonic distortion.

Timer: Used to measure the startup time.

Lifetime testing equipment: used to evaluate the lifespan of light sources.

 

4. Corporate Responsibility

(1) Product Design

Optimize light source design to improve light efficiency, color rendering index, and lifespan.

Choose high-quality electronic components to reduce harmonic distortion.

(2) Compliance testing

Ensure that the product complies with IEC 60969 and GB/T 17263 standards through fluorescent lamp performance testing.

Prepare complete technical documents, including test reports, design drawings, etc.

(3) Labels and identification

Label performance parameters on the product, such as luminous flux, luminous efficiency, color temperature, color rendering index, etc.

Provide instructions for use, including applicable conditions, safety precautions, etc.

 

5. Summary

Fluorescent lamp performance testing is an important method for evaluating the performance of self ballasted fluorescent lamps. According to IEC 60969 and GB/T 17263 standards, it covers indicators such as luminous flux, luminous efficiency, color temperature, color rendering index, start-up time, and lifespan. Enterprises need to optimize product design, ensure product compliance with relevant standards through performance testing, fulfill compliance responsibilities, and enhance product quality and market competitiveness.

6 individual

Large-scale experimental base

150 individual

Professional Lab

30 All kinds of

Analysis Method

8 million times

Testing/year