Photobiosafety

Measure the radiant flux or irradiance of the sample, and classify the hazard levels based on the results

Photobiological safety testing is a crucial method for assessing the potential hazards of light output from light sources or luminous devices (such as LED lights, displays, laser equipment, etc.) on human eyes and skin. By measuring the sample's radiance (W/(sr·m²)) or irradiance (W/m²) and classifying photobiological hazards according to relevant standards, the safety and compliance of products are ensured. Below are the detailed contents of photobiological safety testing:

 

1. Purpose of the Test
Assess the potential hazards of light output from light sources or luminous devices on human eyes and skin.

Classify photobiological hazards based on test results to ensure the product complies with safety standards.

Provide a basis for product design and improvement, reducing the risk of photobiological hazards.

 

2. Testing Principle
Photobiological safety testing is based on photobiological safety standards, measuring the radiance or irradiance of samples across different wavelength ranges to calculate the photobiological weighted radiation dose, and then assessing hazard levels according to relevant standards. The testing covers ultraviolet (UV), visible (VIS), and infrared (IR) wavelength bands.

 

3. Testing Method
(1) Determine test parameters
Wavelength range: typically 200-3000 nm, covering the ultraviolet, visible, and infrared bands.

Measure the distance: Determine based on actual usage (e.g., the distance between the light source and the eyes or skin).

Measurement time: determined according to the test standard (e.g., 100 seconds).

(2) Measure radiance or irradiance
Measure the radiance or irradiance of the sample across different wavelength ranges using a spectroradiometer or photometer.

Ensure the distance and angle between the measuring equipment and the sample comply with the test requirements.

Record radiation data within different wavelength ranges.

(3) Calculate the photosynthetically active radiation
Weight the measured data according to the photobiological hazard functions (such as the ultraviolet hazard function, blue light hazard function, and infrared hazard function).

Calculate the photosynthetically active radiation (PAR) weighted luminance (L_eff) or PAR weighted irradiance (E_eff).

(4) Hazard Level Classification
The photobiological hazards are classified according to relevant standards (e.g., IEC 62471).

Determine the hazard level of the sample (e.g., no hazard, low hazard, medium hazard, high hazard).

 

4. Testing Standards
International Standards:

IEC 62471 (Photobiological safety of lamps and lamp systems).

IEC/TR 62778 (Guidance on Blue Light Hazard Assessment).

Industry Standard:

GB/T 20145 (Photobiological Safety of Lamps and Lamp Systems, China).

ANSI/IESNA RP-27 (American National Standard, Photobiological Safety).

 

5. Test Equipment
Spectroradiometer: Used to measure radiation data across different wavelength ranges.

Radiometer: Used to measure radiant flux or irradiance.

Fixation device: Used to secure samples and measuring equipment, ensuring test stability.

 

6. Data Analysis and Evaluation
Photosynthetically Active Radiation: Calculate the photosynthetically active radiant exitance (L_eff) or photosynthetically active irradiance (E_eff).

Hazard Level: Classification of photobiological hazards according to relevant standards.

Safety distance: Assess the photobiological hazard risks of samples at various distances.

 

7. Hazard Level Classification
According to the IEC 62471 standard, photobiological hazard levels are classified as follows:

No Harm (RG0): Under normal usage conditions, it does not pose a risk of photobiological harm.

Low Hazard (RG1): No photobiological hazards under normal usage conditions, but may cause minor effects with prolonged exposure.

Moderate Hazard (RG2): Under normal usage conditions, it does not pose a photobiological hazard but may cause discomfort with short-term exposure.

High Hazard (RG3): Exposure may cause photobiological hazards even for a short period.

 

8. Common Issues and Solutions
Excessive radiation: possibly due to improper light source design, requiring optimization of the light source's spectral distribution.

High risk level: The product usage scenario may not meet safety requirements. Adjust the usage distance or duration.

Measurement data deviation: May be due to inaccurate calibration of the measuring equipment, requiring recalibration.

 

9. Application scenarios
LED Lighting: Photobiological safety testing for LED lamps and LED displays.

Display device: Optical biological safety testing for devices such as mobile phones, computers, and TV screens.

Laser equipment: Optical biological safety testing for devices such as laser pointers and laser projectors.

Medical equipment: such as photobiological safety testing for medical light sources.

 

10. Test Report
Test conditions: including wavelength range, measurement distance, measurement time, etc.

Test results: including photobiologically weighted radiation, hazard level, safe distance, etc.

Conclusion and Recommendations: Evaluate whether the samples meet the relevant standards and propose improvement suggestions.

Passing the photobiological safety test allows for a comprehensive evaluation of a sample's light output safety, ensuring it does not pose harm to human eyes and skin during practical use while providing a scientific basis for product design and improvement.

6 individual

Large-scale experimental base

150 individual

Professional Lab

30 All kinds of

Analysis Method

8 million times

Testing/year