图片名称

Solutions

Contact Us

图片名称
图片名称

National 24-hour service hotline

400-116-2629

Group Headquarters

Cell phone:18126505465

E-mail: webmaster@lcs-cert.com

Address: Shenzhen City, Baoan District, Shajing Street, Nga side of the school of Wei Juji Industrial Park, Building A 1 ~ 2 floor, Building C 3 floor

Conducted emission voltage method testing

Mainly measuring the interference on the power lines of automotive electronic products, with a frequency range of 0.15~108MHz

Conducted emission voltage testing is a method used to measure electromagnetic interference (EMI) on power lines of automotive electronic products. This test mainly targets interference signals in the frequency range of 0.15~108 MHz, evaluating whether the conducted noise generated by the equipment on the power line meets relevant electromagnetic compatibility (EMC) standards.

 

Test purpose

Evaluate the conducted interference generated by automotive electronic products on power lines.

Ensure that the equipment complies with international and industry standards such as CISPR 25, ISO 7637, etc.

Prevent conducted interference from affecting the normal operation of other electronic systems in the vehicle through power lines.

 

Test Principle

The conducted emission voltage method evaluates the level of conducted interference by measuring the interference voltage on the power line. Testing typically uses a Artificial Power Network (LISN) on the power line to isolate interference between the device under test and the power source, and provide standardized testing conditions.

 

test equipment

Artificial Power Network (LISN):

Used to isolate power interference and provide standardized impedance (usually 50 Ω).

The frequency range should cover 0.15~108 MHz.

Spectrum analyzer or EMI receiver:

Used to analyze the frequency and amplitude of interference signals.

Voltage probe:

Used to measure interference voltage on power lines (if direct measurement is required).

Shielded room or anechoic chamber:

Provide a testing environment without external interference.

 

Test steps

Preparation:

Install the device under test (DUT) on the test bench and connect the power cord.

Ensure that all connections meet the testing standard requirements.

Connect testing equipment:

Connect the LISN to the power cord and connect it to a spectrum analyzer or EMI receiver.

Ensure that the output of LISN is connected to a spectrum analyzer or EMI receiver.

Set test parameters:

Set the frequency range of the spectrum analyzer or EMI receiver to 0.15~108 MHz.

Choose the appropriate scanning step size and resolution bandwidth (RBW).

Conduct testing:

Start the tested device to ensure it is in normal working condition.

Measure the interference voltage on the power line using a spectrum analyzer or EMI receiver, and record the spectrum data.

data analysis

Analyze spectrum data to identify the frequency and amplitude of interference signals.

Compare the test results with the standard limits to determine if they are qualified.

 

Test Standard

CISPR 25: Limits and measurement methods for radio disturbance characteristics for vehicles, ships, and internal combustion engines.

ISO 7637: Road vehicles - Test methods for electrical disturbances caused by conduction and coupling.

OEM standards: Automakers may establish stricter corporate standards.

 

limit requirement

The limit value for conducting emission voltage method testing is usually measured in dB μ V, and the specific limit value depends on the frequency range and testing standards. For example:

0.15~30 MHz: The limit is relatively high, usually ranging from 60~80 dB μ V.

30-108 MHz: The limit is relatively low, usually 50-70 dB μ V.

 

Precautions

Grounding: Ensure that the tested equipment and testing equipment are well grounded to avoid grounding noise affecting the test results.

Shielding: Conduct testing in a shielded room or anechoic chamber to avoid external interference.

Calibration: Calibrate LISN and spectrum analyzer before testing to ensure measurement accuracy.

Equipment status: Ensure that the tested equipment is in a typical working state, covering all possible sources of interference.

 

Common problems and solutions

Excessive interference:

Reason: Insufficient power filtering, unreasonable PCB design, poor grounding, etc.

Solution: Add filters, optimize PCB layout, and improve grounding design.

The test results are unstable:

Reason: External interference, unstable device operation status.

Solution: Test in a shielded environment to ensure consistent device operation.

 

Application field

Automotive electronics: in car entertainment systems, engine control units (ECUs), sensors, etc.

Industrial electronics: industrial controllers, motor drivers, etc.

Consumer electronics: smart devices, household appliances, etc.

 

Conclusion

Conducting emission voltage testing is an important means of evaluating the electromagnetic compatibility of automotive electronic products. By measuring the conducted interference on the power line, potential EMI issues can be identified and resolved, ensuring that the equipment complies with relevant standards and meets the electromagnetic compatibility requirements of the entire vehicle. During the testing process, attention should be paid to equipment calibration, environmental shielding, and data analysis to ensure the accuracy and reliability of the test results.

6 individual

Large-scale experimental base

150 individual

Professional Lab

30 All kinds of

Analysis Method

8 million times

Testing/year