Alternating cycle

This test is used to determine the ability of components, equipment, or other products to withstand normal changes in ambient temperature.

Test purpose
Evaluate the tolerance of components, equipment, or other products under normal environmental temperature changes, and detect the performance degradation or failure of materials caused by temperature cycling changes.

 

Test Standard
According to the standard:

IEC 60068-2-14: Environmental testing - Part 2: Test method N (temperature variation)

GB/T 2423.22: Environmental testing for electrical and electronic products (temperature changes)

MIL-STD-810: Environmental Engineering Considerations and Laboratory Testing

 

Test Principle
Evaluate the performance stability of the product in temperature fluctuation environments by simulating the temperature cycling conditions that the product may encounter during actual use or storage.

test equipment
High and low temperature alternating test chamber

 

Temperature Recorder

Sample holder

Assessment tools (microscopes, electrical performance testers, etc.)

Test steps
Sample preparation:

Clean the surface of the sample to ensure that there are no oil stains or other contaminants.

Record the initial state of the sample (taking photos, conducting electrical performance tests, etc.).

Fix the sample inside the test chamber and ensure that the exposed surface is uniformly heated.

 

Test condition settings:

High temperature limit: set according to demand (usually+85 ℃ to+150 ℃).

Low temperature limit: set according to demand (usually -40 ℃ to -65 ℃).

Temperature change rate: set according to demand (usually 1 ℃/min to 5 ℃/min).

Residence time: Set according to requirements (usually 30 minutes to 1 hour).

Cycle times: Set according to demand (usually 50-100 times).

 

Test Run:

Start the test chamber and perform temperature cycling according to the set conditions.

Each cycle includes:

Raise the room temperature to the high temperature limit and maintain the residence time.

Reduce from high temperature limit to low temperature limit and maintain residence time.

Raise from the low temperature limit to room temperature.

Repeat the above cycle until the set number of times is completed.

 

Test completed:

Take out the sample and restore it to a standard environment for 24 hours.

Record the status of the sample after testing (taking photos, conducting electrical performance tests, etc.).

Result evaluation:

Appearance inspection:

Check whether there are cracks, deformations, delamination, and other phenomena in the sample.

Electrical performance testing:

Evaluate the electrical performance changes of components (such as resistance, capacitance, insulation resistance, etc.).

Mechanical performance testing:

Evaluate the changes in properties such as tensile strength and impact strength of materials.

Microstructure analysis:

Observe surface microstructural changes using a microscope.

 

Precautions
Ensure the accuracy of the temperature change rate and residence time in the test chamber to avoid deviations in testing conditions.

The sample should be placed evenly to avoid local overheating or overcooling.

After the test is completed, the sample needs to be restored to a standard environment before evaluation.

 

Test Record
Record the testing conditions (high temperature limit, low temperature limit, temperature change rate, residence time, number of cycles, etc.).

Record the initial and post test states of the sample (taking photos, conducting electrical performance tests, etc.).

Record the specific manifestations of material performance changes.

 

Conclusion
Based on the test results, evaluate the product's tolerance performance in alternating cyclic environments and issue a test report. Through this test, important basis can be provided for product design, material selection, and process improvement, ensuring the reliability of the product in temperature fluctuation environments.