图片名称

Solutions

Contact Us

图片名称
图片名称

National 24-hour service hotline

400-116-2629

Group Headquarters

Cell phone:18126505465

E-mail: webmaster@lcs-cert.com

Address: Shenzhen City, Baoan District, Shajing Street, Nga side of the school of Wei Juji Industrial Park, Building A 1 ~ 2 floor, Building C 3 floor

Solid foreign object prevention test

According to different levels of IP1X~4X, the structure of the test sample's shell to prevent external foreign objects

The solid foreign object prevention test is a key test to evaluate the ability of the product casing to prevent external foreign objects from entering. The testing methods and requirements vary depending on the IP protection level (IP1X~IP4X). The following are the testing steps and evaluation points:

 

1. Test preparation
Sample selection: Select representative product samples for testing.

Testing equipment: Prepare corresponding testing tools according to the IP level, such as testing probes, steel balls, dust boxes, etc.

Standard basis: Refer to IEC 60529 standard to clarify the specific requirements for different IP levels.

 

2. Definition of IP1X~IP4X levels
IP1X: Prevent solid foreign objects with a diameter of ≥ 50mm from entering.

IP2X: Prevent solid foreign objects with a diameter of ≥ 12.5mm from entering.

IP3X: Prevent solid foreign objects with a diameter of ≥ 2.5mm from entering.

IP4X: Prevent solid foreign objects with a diameter of ≥ 1.0mm from entering.

 

3. Testing steps
IP1X test
Testing tool: Use a spherical object with a diameter of 50mm (such as a steel ball).

Testing method: Attempt to insert a spherical object into the opening of the housing, ensuring that it cannot fully enter.

Judgment criteria: Spherical objects must not completely pass through the opening of the shell.

IP2X testing
Testing tool: Use a spherical object with a diameter of 12.5mm.

Testing method: Attempt to insert a spherical object into the opening of the housing, ensuring that it cannot fully enter.

Judgment criteria: Spherical objects must not completely pass through the opening of the shell.

IP3X testing
Testing tool: Use a 2.5mm diameter testing probe.

Test method: Attempt to insert the probe into the opening of the housing and apply a force not exceeding 1N.

Judgment criteria: The probe must not enter the interior of the casing.

IP4X testing
Testing tool: Use a 1.0mm diameter testing probe.

Test method: Attempt to insert the probe into the opening of the housing and apply a force not exceeding 1N.

Judgment criteria: The probe must not enter the interior of the casing.

 

4. Post test evaluation
Appearance inspection: Check for any deformation, damage, or traces of probe entry on the casing.

Functional inspection: Test the electrical and mechanical performance of the product to ensure that its functionality is not affected.

Judgment result: Based on the test results, confirm whether the product meets the requirements of the corresponding IP level.

 

5. Improvement measures
Structural optimization: Optimize the shell design based on test results, such as adding protective nets, reducing opening sizes, etc.

Material improvement: Choose stronger materials to enhance the impact resistance and protection of the shell.

Sealing design: Improve the sealing structure to ensure that the shell can effectively prevent foreign objects from entering.

 

6. Compliance with standards
International standards: Ensure that testing methods and evaluation criteria comply with IEC 60529 standards.

Certification requirements: Ensure that the product meets the certification requirements of the relevant industry or region based on its intended use.

Through the above steps, the ability of the product casing to prevent solid foreign objects can be comprehensively evaluated, ensuring that it can meet the protection requirements at different IP levels.

6 individual

Large-scale experimental base

150 individual

Professional Lab

30 All kinds of

Analysis Method

8 million times

Testing/year