Temperature sensitive controller

Temperature sensitive controllers (such as thermostats, thermal protectors, etc.) are devices used to monitor and control temperature, widely used in household appliances, industrial equipment, and automobiles. Its design and manufacturing need to meet a series of strict safety and performance requirements. The following are detailed requirements for temperature sensitive controllers in terms of data requirements, anti electric shock protection, grounding protection, etc.:

 

1. Data requirements
Technical documents: including product specifications, circuit diagrams, material lists, test reports, etc.

Signs and instructions: The product should have clear signs (such as rated voltage, current, temperature range, etc.) and provide detailed user manuals.

Certification information: Complies with relevant standards and certification requirements (such as UL, CE, RoHS, etc.).

 

2. Anti electric shock protection
Shell protection: The shell of the controller should be able to prevent users from accidentally coming into contact with live parts, usually achieved through insulation materials or protective covers.

Hole restriction: The holes on the shell should meet the standard requirements to prevent fingers or tools from entering and contacting live parts.

Protection level: It should meet the requirements of IP (Ingress Protection) protection level, such as IP20, IP44, etc.

 

3. Grounding protection
Grounding terminal: The controller should be equipped with reliable grounding terminals to ensure grounding continuity.

Grounding marking: The grounding terminal should have clear markings (such as the grounding symbol "⏚").

Grounding resistance: The grounding resistance should meet the standard requirements (usually less than 0.1 Ω).

 

4. Terminals and tips
Reliable connection: The terminals and ends should be securely connected to prevent loosening or detachment.

Suitable wire specifications: The terminals and ends should be suitable for the wire specifications and provide sufficient clamping force.

Insulation protection: The connection should have insulation protection to prevent short circuit or electric shock.

 

5. Structural requirements
Mechanical strength: The structure of the controller should have sufficient mechanical strength to withstand the stress during installation and use.

Durable materials: The outer shell and internal structural materials should be corrosion-resistant and aging resistant.

Easy installation: The design should be easy to install and maintain.

 

6. Moisture and dust prevention
Moisture proof and waterproof: It should meet the requirements of IP protection level (such as IP44, IP65, etc.) to prevent moisture and water from entering.

Dustproof: The casing should be able to prevent dust and solid foreign objects from entering.

 

7. Electrical strength and insulation strength
Insulation resistance: Under standard testing conditions, the insulation resistance should meet the requirements (usually greater than 10M Ω).

Electrical strength: It should be able to withstand the specified withstand voltage test (such as 1500V/1 minute) without breakdown.

 

8. Fever
Temperature limit: Under rated load, the temperature rise of the controller should meet the standard requirements (usually not exceeding 50K).

Material heat resistance: The material should be able to withstand high temperatures without deformation or failure.

 

9. Manufacturing deviation and drift
Accuracy requirements: The temperature control accuracy of the controller should meet the design requirements, and manufacturing deviations and drifts should be within the allowable range.

Calibration: Calibration should be performed before leaving the factory to ensure stable performance.

 

10. Environmental stress
High and low temperature resistance: The controller should be able to operate normally within the specified temperature range (such as -40 ° C to+85 ° C).

Moisture and heat resistance: It should be able to withstand high humidity environments to prevent performance degradation.

 

11. Durability
Life testing: The controller should pass durability testing (such as switch life testing) to ensure its service life under rated load.

Material durability: The material should be resistant to aging and wear.

 

12. Mechanical strength
Impact resistance: The shell should be able to withstand a certain mechanical impact without breaking.

Pressure resistance: It should be able to withstand a certain amount of pressure without deformation or damage.

 

13. Threaded components and connections
Reliable connection: Threaded components should be securely connected to prevent loosening or detachment.

Material strength: Threaded components should have sufficient mechanical strength to withstand stress during installation and use.

 

14. Creepage distance, electrical clearance, and sealant penetration distance
Electrical clearance: The minimum air distance between live parts should meet the standard requirements.

Creepage distance: The minimum distance along the insulation surface should meet the standard requirements to prevent arcing or leakage.

Penetration distance of sealant: The thickness and performance of the sealant should meet the standard requirements to prevent leakage or short circuit.

 

15. Heat resistance, flame resistance, and leakage resistance
Heat resistance: The material should be able to withstand high temperatures without softening or deforming.

Flame resistance: The material should have flame retardant properties and pass the hot wire test or needle flame test.

Anti leakage marking: The material should be able to withstand leakage marking phenomena (such as leakage marking tests) to prevent surface carbonization from causing short circuits.

 

16. Corrosion resistance
Corrosion resistance of materials: The outer shell and internal metal components should be corrosion-resistant (such as salt spray test).

Surface treatment: Metal components should undergo anti-corrosion treatment (such as galvanizing, spraying).

 

17. Electromagnetic Compatibility Requirements - Emission and Immunity (EMC)
Anti interference: The controller should be able to resist external electromagnetic interference (such as electrostatic discharge, radio frequency interference).

Low radiation: The controller should not generate excessive electromagnetic radiation, which may affect the normal operation of other devices.

Compliance with standards: It should comply with relevant EMC standards (such as GB/T 17626, IEC 61000 series).

 

18. Normal operation
Functional testing: Under normal operating conditions, the controller should be able to accurately monitor and control temperature.

Stability: During long-term operation, performance should remain stable.

 

19. Abnormal operation
Fault protection: Under abnormal operating conditions (such as overload, short circuit, etc.), the controller should have protective functions to prevent damage or danger.

Safety design: Safety mechanisms should be designed to prevent accidents caused by misoperation.

 

20. Guidelines for the use of electronic disconnection
Disconnecting function: The controller should have electronic disconnection function to ensure safe disconnection of the circuit in case of faults or abnormalities.

Instructions for use: Provide detailed electronic disconnection usage guidelines to ensure users operate correctly.

 

summary
The design and manufacturing of temperature sensitive controllers require comprehensive consideration of multiple factors such as electrical safety, mechanical strength, environmental adaptability, and durability. By meeting the above requirements, the reliability, safety, and durability of the controller can be ensured in various application scenarios, while complying with relevant standards and certification requirements.

6 individual

Large-scale experimental base

150 individual

Professional Lab

30 All kinds of

Analysis Method

8 million times

Testing/year