Beam angle test

The angle between two directions with a light intensity equal to 50% of the maximum light intensity on a plane perpendicular to the centerline of the beam.

Beam Angle is an important parameter that describes the range of light distribution in a lighting fixture. It is defined as the angle between two directions on a plane perpendicular to the centerline of the beam, where the light intensity is equal to 50% of the maximum light intensity. The following is a detailed explanation of the beam angle:

 

1. Definition of beam angle
Beam angle is an indicator of the degree of concentration or dispersion of light in a lighting fixture. It represents the distribution range of light in space:

Small beam angle (such as 10 ° -20 °): The light is concentrated and suitable for focused lighting or long-distance illumination.

Large beam angle (such as 60 ° -120 °): The light is dispersed and suitable for large-area illumination or close range illumination.

 

2. Measurement method of beam angle
The testing of beam angle usually includes the following steps:

Fixed light fixture: Install the light fixture on the testing equipment, ensuring that its beam centerline is perpendicular to the testing plane.

Measure light intensity distribution: Use a spectrophotometer to measure the light intensity distribution of the lamp on the test plane.

Determine the 50% intensity point: Find the two directions where the light intensity is equal to 50% of the maximum light intensity.

Calculate angle: Measure the angle between these two directions, which is the beam angle.

 

3. The relationship between beam angle and light distribution curve
The beam angle can be visually represented by the light distribution curve:

In the light distribution curve, the angle corresponding to the point with 50% maximum light intensity is the beam angle.

The shape (narrow or wide) of the light distribution curve reflects the size of the beam angle.

 

4. Application of Beam Angle
Lighting design: Select the appropriate beam angle based on lighting requirements.

Small beam angle: used for key lighting, such as spotlights and track lights.

Large beam angle: used for floodlighting, such as tube lights and panel lights.

Lamp selection: Help users choose lamps that are suitable for the scene.

For example, galleries require small beam angle lighting fixtures to highlight exhibits, while offices require large beam angle lighting fixtures to provide uniform illumination.

Performance evaluation: Evaluate the light distribution characteristics of the lighting fixture.

 

5. Factors affecting beam angle
Light source type: Different light sources such as LED and halogen lamps have different beam angle characteristics.

Optical design: Reflectors, lenses, and other optical components can affect the beam angle.

Lamp structure: The shape and size of the lamp can also affect the distribution of light.

 

6. Example of beam angle
Narrow beam angle (10 ° -20 °): used for stage spotlights and museum exhibit lighting.

Medium beam angle (30 ° -45 °): used for shop window lighting and residential key lighting.

Wide beam angle (60 ° -120 °): used for large-area lighting in offices, classrooms, etc.

 

7. The relationship between beam angle and lighting effect
Small beam angle: concentrated light, high brightness, suitable for long-distance illumination or highlighting key areas.

Large beam angle: The light is dispersed and uniform, suitable for large-area lighting or creating a soft atmosphere.

By testing and selecting appropriate beam angles, the lighting effect can be optimized to meet the lighting needs of different scenes.