Electromagnetic wave absorption ratio SAR test

SAR, The full name is Specific Absorption Rate, which refers to the electromagnetic waves absorbed or consumed per unit mass of human tissue. The unit is W/Kg or MW/g. It refers to the measured energy absorption rate of the human body when exposed to radio frequency electromagnetic fields. SAR testing mainly targets wireless products with antennas within 20cm of the human body. It is used to protect us from wireless devices that exceed the RF transmission value. Not all products with wireless transmission antennas within 20cm of the human body require SAR testing. Each country has other testing methods called MPE evaluation, based on products that meet the above conditions but have lower power.

 

The electromagnetic absorption ratio (SAR) test is a key test for evaluating the amount of electromagnetic radiation absorbed by the human body by electronic devices (such as mobile phones) during use. The following are the main contents and steps of SAR testing:

1. Definition of SAR
SAR (Specific Absorption Rate) represents the electromagnetic power absorbed by a unit mass of human tissue, measured in W/kg.

 

2. Test purpose
Safety assessment: Ensure that equipment radiation is within safe limits.

Compliance: Meet the electromagnetic radiation standards of various countries or regions, such as FCC (United States), ICNIRP (Europe), etc.

 

3. Testing equipment
SAR testing system: including probe, scanning system, signal generator, etc.

Human body model: a phantom filled with simulated human tissue fluid.

Positioning device: Accurately fix the tested equipment.

 

4. Testing steps
prepare

Calibrate testing equipment.

Set the device to maximum transmission power.

location:

Place the device at the head or body position of the human body model to simulate actual usage scenarios.

Scan:

Scan the model with a probe and measure the electric field strength.

Data collection

Record the electric field strength at each point and calculate the SAR value.

Analysis:

Calculate the average SAR value to ensure it is within safe limits.

 

5. Testing standards
FCC: Federal Communications Commission, with a limit of 1.6 W/kg (1 gram organization average).

ICNIRP: International Commission on Non Ionizing Radiation Protection, with a limit of 2.0 W/kg (10 gram tissue average).

 

6. Test report
After the testing is completed, generate a report that includes:

test conditions

Test results

Conclusion (whether it meets the standards)

 

7. Precautions
Environmental control: Ensure that the testing environment is interference free.

Equipment status: The equipment needs to be at maximum transmission power.

Model maintenance: Regularly check the performance of the human body model and simulation fluid.

 

8. Common Problems
SAR value too high: Equipment design or antenna position needs to be adjusted.

Inconsistent test results: Check equipment calibration and testing environment.

 

9. Relevant regulations
FCC Part 2 and Part 24: RF exposure requirements for wireless devices in the United States.

EN 62209-1 and EN 62209-2: European SAR testing standards.

 

10. Summary
SAR testing is a key step in ensuring the electromagnetic radiation safety of electronic devices, and it is necessary to strictly follow standards and specifications to ensure that the equipment meets safety requirements.

Through the above steps, SAR testing can effectively evaluate the electromagnetic radiation safety of equipment and ensure user health.