Electric leakage trace

After simulating dust and water entering the lamp, they adhere to the surface of the insulation material. Under the combined action of electric field and water containing impurities, the surface of the insulation material leaks or partially discharges, forming a stable conductive path that induces corrosion and damages its insulation performance

 

After simulating dust and water entering the lamp, they adhere to the surface of the insulation material. Under the combined action of electric field and water containing impurities, the surface of the insulation material leaks or partially discharges, forming a stable conductive path that induces corrosion and damages its insulation performance

 

Tracking Resistance Test is an experimental method for evaluating the anti leakage performance of insulation materials in electric fields and polluted environments. It simulates the situation where pollutants such as dust and moisture enter the lamp and adhere to the surface of the insulation material, forming a conductive path under the action of an electric field, resulting in a decrease or even failure of the material's insulation performance. The following is a detailed explanation of the leakage trace test:

 

Test Principle
Apply voltage on the surface of the insulation material and drip a contaminated solution containing electrolyte (such as ammonium chloride solution) to simulate pollutants and humid environment. Under the action of an electric field, partial discharge may occur on the surface of the material, forming conductive pathways and ultimately leading to insulation failure. Through testing, the anti leakage and anti tracking performance of the material can be evaluated.

 

Test Standard
Common standards for leakage trace testing include:

IEC 60112: International Electrotechnical Commission standard, widely used for residual current tracing testing of electrical insulation materials.

ASTM D3638: American Society for Testing and Materials standard, used to evaluate the electrical leakage resistance of solid insulation materials.

GB/T 4207: Chinese National Standard, equivalent to IEC 60112.

 

test equipment
Electrode:

Use platinum or stainless steel electrodes, with electrode shape and size meeting standard requirements.

Polluting liquid:

Usually, 0.1% or 1% ammonium chloride (NH ₄ Cl) solution is used to simulate water containing impurities.

Power Supply:

Provide AC or DC voltage ranging from 100V to 600V, with specific voltage determined according to testing requirements.

Dropping device:

Control the droplet acceleration of the contaminated liquid (such as every 30 seconds).

 

Test steps
Sample preparation:

Prepare standard sized samples (usually 15mm x 15mm x 4mm).

Clean the surface of the sample to ensure no contamination.

Installation sample:

Fix the sample on the testing device to ensure good contact between the electrode and the sample surface.

Applied voltage:

Apply voltage according to testing standards (such as 175V, 250V, 400V, etc.).

Drip contaminated liquid:

Use a drip device to add contaminated liquid between the electrodes and control the drip acceleration.

Observation record:

Observe whether there are traces of electrical leakage, partial discharge, or the formation of conductive pathways on the surface of the sample.

Record the trace time, trace length, and whether combustion or carbonization has occurred.

Termination conditions:

When a stable conductive path is formed on the surface of the sample, or when the specified number of drops (such as 50 drops) is reached, the test is terminated.

 

result evaluation
According to the test results, the anti leakage and anti tracking performance of materials is usually divided into the following levels:

CTI(Comparative Tracking Index):

The highest voltage value that the material can withstand during testing (at intervals of 25V), the higher the CTI value, the better the material's resistance to leakage.

PTI(Proof Tracking Index):

The ability of materials to pass tests at specific voltages.

 

Test points
Pollutant concentration: Ensure that the concentration and droplet velocity of the pollutant meet the standard requirements.

Electrode cleaning: Clean the electrodes before each test to avoid residue affecting the results.

Environmental control: Testing should be conducted under standard temperature and humidity conditions.

Safety protection: Harmful gases may be generated during the testing process, and ventilation equipment is required.

 

application
Lamp industry: Evaluate the anti leakage performance of lamp housings and insulation components.

Electronic and electrical industry: testing the reliability of insulation materials such as circuit boards, sockets, switches, etc.

Automotive industry: Evaluate the durability of insulation materials in automotive electrical systems.

Through leakage tracing testing, the performance of insulation materials in polluted environments can be effectively evaluated, providing a basis for product design and safety certification.