Low frequency magnetic field emission test

The EMC low-frequency magnetic field emission test is mainly used to detect whether electronic and electrical products generate significant low-frequency magnetic field radiation during operation, in order to determine whether these radiations will affect other electronic and electrical equipment and the human body in the surrounding area. Specifically, the testing frequency range usually includes 10 Hz to 30 MHz, and the low-frequency magnetic field radiation detected in these frequency bands mainly comes from electrical components such as power supplies, switches, timers, and coils of electronic and electrical products. The working process of these components and coils may generate low-frequency magnetic fields, which may have adverse effects on other surrounding devices and the human body;

 

Test purpose

Evaluate the magnetic field radiation level of electronic and electrical products in the low-frequency range.

Ensure that the product complies with relevant electromagnetic compatibility (EMC) standards.

Prevent low-frequency magnetic field radiation from causing adverse effects on other devices and human health.

 

Test Principle

The low-frequency magnetic field emission test evaluates the radiation level by measuring the magnetic field strength generated by the device in space. Testing typically uses magnetic field probes and receivers to capture low-frequency magnetic field signals and analyze their frequency and amplitude.

 

test frequency

Typical frequency range: 10 Hz~30 MHz.

Focus on frequency bands:

50 Hz/60 Hz: Power frequency interference from power lines.

KHz~MHz: High frequency interference from switching power supplies, timers, and coils.

 

test equipment

Magnetic field probe:

Used to measure low-frequency magnetic field strength, it usually includes a ring probe and a three-axis probe.

Receiver or spectrum analyzer:

Used to analyze the frequency and amplitude of magnetic field signals.

Radio anechoic chamber or shielding room:

Provide a testing environment without external interference.

Pre amplifier:

Used to amplify weak signals and improve testing sensitivity.

 

Test steps

Preparation:

Install the device under test (DUT) on the test bench and connect all necessary cables and power sources.

Ensure that the equipment is in normal working condition.

Set up testing environment:

Install magnetic field probes and receivers in anechoic or shielded rooms.

Calibrate the testing system to ensure measurement accuracy.

Conduct testing:

Start the tested device and put it in typical working mode.

Measure the magnetic field strength at different positions and directions using a magnetic field probe.

Record spectrum data, including frequency, amplitude, and magnetic field direction.

data analysis

Analyze spectrum data to identify the frequency and amplitude of magnetic field radiation.

Compare the test results with the standard limits to determine if they are qualified.

 

Test Standard

CISPR 16: Radio disturbance and immunity measurement equipment and methods.

IEC 61000-4-8: Power frequency magnetic field immunity test.

EN 55011: Radio disturbance limits and measurement methods for industrial, scientific, and medical equipment.

 

limit requirement

The limit values for low-frequency magnetic field emission testing are usually measured in dBpT or A/m, depending on the frequency range and testing standards. For example:

50 Hz/60 Hz: The limit is usually between 1 A/m and 10 A/m.

KHz~MHz: The limit is usually 0.01 A/m~0.1 A/m.

 

Precautions

Test environment: Ensure that there is no external interference in the anechoic chamber or shielding room.

Equipment status: Ensure that the tested equipment is in typical working condition, covering all possible radiation sources.

Probe calibration: Regularly calibrate the magnetic field probe and receiver to ensure measurement accuracy.

Test distance: Set the test distance according to standard requirements (such as 3 meters, 10 meters).

 

Common problems and solutions

Excessive magnetic field radiation:

Reason: Unreasonable power supply design, improper coil layout, insufficient shielding, etc.

Solution: Optimize power supply design, adjust coil layout, and add shielding measures.

The test results are unstable:

Reason: External interference, unstable device operation status.

Solution: Test in a shielded environment to ensure consistent device operation.

 

Application field

Household appliances: refrigerators, washing machines, air conditioners, etc.

Industrial equipment: motors, transformers, power modules, etc.

Medical equipment: MRI, X-ray machine, etc.

Automotive electronics: electric vehicle chargers, motor drivers, etc.

 

Conclusion

EMC low-frequency magnetic field emission testing is an important means of evaluating the electromagnetic compatibility of electronic and electrical products. By measuring the magnetic field radiation level of the equipment in the low-frequency range, potential EMI issues can be identified and resolved, ensuring that the equipment complies with relevant standards and meets electromagnetic compatibility requirements. During the testing process, attention should be paid to the testing environment, equipment status, and data analysis to ensure the accuracy and reliability of the test results.