图片名称

Solutions

Contact Us

图片名称
图片名称

National 24-hour service hotline

400-116-2629

Group Headquarters

Cell phone:18126505465

E-mail: webmaster@lcs-cert.com

Address: Shenzhen City, Baoan District, Shajing Street, Nga side of the school of Wei Juji Industrial Park, Building A 1 ~ 2 floor, Building C 3 floor

Strength testing of various fixed supports

According to different standards, evaluate the strength of the fixed bracket of the entire sample or component using different methods such as thrust, tension, and bending force.

 

When evaluating the strength of various fixed brackets, tests such as thrust, tension, and bending forces are usually conducted according to different standards and testing methods to ensure their reliability and safety in practical applications. The following are common testing methods and evaluation points:

 

1. Thrust test
Purpose: To evaluate the compressive strength of the bracket when subjected to thrust.

Application scenario: Suitable for supporting structures or load-bearing brackets.

Test method: Apply a thrust perpendicular to the surface of the bracket and gradually increase the load until the bracket deforms or breaks.

Evaluation indicators: maximum thrust, deformation, and failure mode.

 

2. Tensile testing
Purpose: To evaluate the tensile strength of the stent under tension.

Application scenario: Suitable for suspension structures or supports that can withstand tension.

Test method: Apply tension and gradually increase the load until the bracket breaks or fails.

Evaluation indicators: maximum tensile strength, fracture point, and ductility.

 

3. Bending force test
Purpose: To evaluate the bending strength of the bracket under bending force.

Application scenario: Suitable for brackets that can withstand bending loads.

Testing method: By applying bending force, gradually increase the load until the bracket undergoes plastic deformation or fracture.

Evaluation indicators: maximum bending force, bending angle, and deformation.

 

4. Shear force test
Purpose: To evaluate the shear strength of the stent under shear stress.

Application scenario: Suitable for brackets or connecting components that can withstand shear forces.

Test method: Apply shear force and gradually increase the load until the bracket undergoes shear failure.

Evaluation indicators: maximum shear force, failure mode.

 

5. Fatigue testing
Purpose: To evaluate the durability of the stent under long-term cyclic loading.

Application scenario: Suitable for brackets that can withstand periodic loads.

Testing method: Simulate cyclic loads in actual use by repeatedly applying thrust, tension, or bending forces until the bracket fails.

Evaluation indicators: fatigue life, number of cycles, failure mode.

 

6. Environmental simulation testing
Purpose: To evaluate the strength performance of the stent under different environmental conditions.

Application scenario: Suitable for brackets used in extreme temperature, humidity, corrosion and other environments.

Testing method: Place the bracket in a simulated environment (such as high temperature, low temperature, humidity, salt spray, etc.), and then conduct tests on thrust, tension, bending force, etc.

Evaluation indicators: changes in strength under environmental conditions, degree of corrosion, durability.

 

7. Overall and component testing
Overall testing: Evaluating the overall strength and stability of the bracket, usually simulating actual usage scenarios.

Component testing: Conduct separate testing on key components of the bracket (such as connectors, supports, etc.) to ensure their strength and reliability.

 

8. Standard Basis
International standards: testing methods for bracket strength in standards such as ISO, ASTM, EN, etc.

Industry standards: Develop corresponding testing standards based on the specific requirements of different industries such as construction, automotive, aerospace, etc.

Enterprise standard: Develop internal testing standards based on the company's own product design and application requirements.

 

9. Testing equipment
Universal material testing machine: used for testing thrust, tension, bending force, etc.

Fatigue testing machine: used for fatigue testing under cyclic loading.

Environmental testing chamber: used to simulate testing under different environmental conditions.

 

10. Data analysis and reporting
Data recording: Record data such as load, deformation, and fracture points during the testing process.

Result analysis: Analyze the strength, deformation mode, failure reasons, etc. of the bracket.

Test report: Generate a detailed test report, including testing methods, result analysis, conclusions, and recommendations.

Through the above tests, the strength performance of the fixed bracket can be comprehensively evaluated to ensure its safety and reliability in practical applications.

6 individual

Large-scale experimental base

150 individual

Professional Lab

30 All kinds of

Analysis Method

8 million times

Testing/year