Luminous flux (emergency light)

Test the light output of the sample, compare it with the declared value and local regulations, and determine whether it meets the requirements of emergency lighting

Luminous flux detection is an important testing method for evaluating the light output performance of emergency lights, such as emergency lighting fixtures, evacuation indicator lights, etc. By measuring the luminous flux of the sample (in lumens, lm) and comparing it with the declared value of the product and local regulatory requirements, determine whether it meets emergency lighting requirements. The following is the detailed content of luminous flux detection:

 

1. Test purpose

Evaluate the light output performance of emergency lights to ensure that their luminous flux meets the product's declared value.

Compare local regulatory requirements to determine whether emergency lights meet the minimum luminous flux standard.

Verify whether the product can provide sufficient lighting brightness in actual use to ensure the safe evacuation of personnel.

 

2. Testing principle

Luminous flux refers to the total amount of visible light emitted by a light source per unit time, measured in lumens (lm). Measure the luminous flux of emergency lights using an integrating sphere or a distributed photometer to evaluate their light output performance.

 

3. Testing methods

(1) Determine test parameters

Measurement equipment: Use an integrating sphere or a distributed photometer to measure luminous flux.

Environmental conditions: Conduct testing in a dark or semi dark room to avoid interference from ambient light.

Test time: Ensure that the emergency light is measured in a stable working state (such as after being lit for 5 minutes).

(2) Measure luminous flux

Install the emergency light in the integrating sphere or distributed photometer to ensure that it is in normal working condition.

Measure the luminous flux value of the sample using a photometer.

Record the measurement results and compare them with the declared values of the product.

(3) Compare local regulations

Determine the minimum luminous flux requirements according to local regulations in the installation area (such as GB 17945, EN 1838, etc.).

Compare the measurement results with regulatory requirements to determine if they meet emergency lighting requirements.

(4) Evaluate the stability of light output

Measure the luminous flux regularly throughout the entire working time of the emergency light (e.g. 90 minutes).

Evaluate the stability of light output to ensure it can provide sufficient illumination continuously in emergency situations.

 

4. Testing standards

International standards:

IEC 60598-2-22 (Safety requirements for emergency lighting fixtures).

ISO 30061 (Requirements for emergency lighting).

Industry standards:

GB 17945 (Fire Emergency Lighting and Evacuation Indication System, China).

EN 1838 (Emergency Lighting and Sign Lights, Europe).

 

 

5. Testing equipment

Integral sphere: used for measuring luminous flux, suitable for small light sources.

Distributed photometer: used to measure luminous flux and intensity distribution, suitable for large lighting fixtures.

Photometer: used to measure luminous flux values.

Darkroom or semi darkroom: used to provide an interference free testing environment.

 

6. Data analysis and evaluation

Luminous flux value: Record the measured luminous flux value of the sample and compare it with the declared value of the product.

Regulatory comparison: Compare the measurement results with the minimum luminous flux requirements of local regulations to determine compliance.

Light output stability: Evaluate the light output stability of emergency lights throughout the entire working time.

 

7. Common problems and solutions

Insufficient luminous flux: It may be due to aging of the light source or unreasonable design, requiring replacement of the light source or optimization of the design.

Not matching the claimed value: It may be due to inconsistent product testing conditions with the claimed conditions, requiring retesting or adjustment of the claimed value.

Unstable light output: It may be a problem with the power supply or drive circuit, and the power supply or drive circuit needs to be checked.

 

8. Application scenarios

Fire safety: such as detecting the luminous flux of emergency lighting and evacuation indicator lights.

Building safety: testing of emergency lighting systems in office buildings, shopping malls, and hospitals.

Industrial safety: such as testing emergency lighting systems in factories and warehouses.

 

9. Test report

Testing conditions: including measuring equipment, environmental conditions, testing time, etc.

Test results: including measured luminous flux values, comparison with declared values, comparison with regulatory requirements, etc.

Conclusion and Suggestions: Evaluate whether the sample meets the relevant standards and propose improvement suggestions.

Through luminous flux detection, the light output performance of emergency lights can be comprehensively evaluated to ensure that they can meet emergency lighting requirements in practical use and ensure the safe evacuation of personnel.