Temperature rise test

Under normal operation, the temperature at each location of the equipment cannot exceed the maximum temperature of the corresponding component.

Temperature rise test is a testing method used to evaluate the temperature changes of various parts of equipment under normal working conditions. By measuring the temperature of key parts of the equipment during operation, it is ensured that it does not exceed the specified maximum allowable temperature, thereby ensuring the safety and reliability of the equipment. The following is a detailed explanation of the temperature rise test:

 

Test purpose

The main purpose of temperature rise testing is to:

Evaluate the temperature distribution of the equipment under normal operating conditions.

Ensure that the temperature of each part of the equipment does not exceed the maximum allowable temperature of the material or component.

Verify whether the heat dissipation design of the device is reasonable to avoid malfunctions or safety hazards caused by overheating.

 

Test Principle

The temperature rise test is based on the following principles:

The equipment operates under rated working conditions and simulates actual usage scenarios.

Use temperature measuring devices (such as thermocouples, infrared thermometers, etc.) to monitor the temperature of key parts of the equipment.

Record temperature data and compare it with the specified maximum allowable temperature.

 

test equipment

Temperature measurement equipment:

Thermocouple: Used for contact temperature measurement with high accuracy.

Infrared thermometer: used for non-contact temperature measurement, suitable for hard to reach areas.

Data logger: used to continuously record temperature data.

Load device:

Used to simulate the load conditions of equipment in actual use.

Environmental testing chamber (optional):

Used to control the temperature of the testing environment and simulate different working environments.

 

Test steps

Prepare equipment:

Ensure that the equipment is in normal working condition and all components are installed correctly.

Identify the key areas that need to be monitored (such as power supply, motor, circuit board, casing, etc.).

Install temperature sensor:

Install thermocouples or other temperature sensors at critical locations to ensure good contact.

For non-contact measurement, use an infrared thermometer to align with the measurement site.

Set testing conditions:

Operate the equipment under rated working conditions (such as rated voltage, rated load, etc.).

If using an environmental test chamber, set the ambient temperature (such as 25 ° C or 40 ° C).

Start testing:

Start the device and operate it under rated conditions.

Record the temperature data of each part, usually every 5-10 minutes.

Continuous operation:

Keep the device running until the temperature stabilizes (usually takes 1-2 hours).

Record stable temperature data.

End of Test:

Stop the device operation and analyze the temperature data.

Check if the temperature of each part exceeds the maximum allowable temperature specified.

 

Qualification Standard

The qualification criteria for temperature rise testing are usually:

Maximum allowable temperature:

The temperature of each part of the equipment shall not exceed the maximum allowable temperature of the material or component.

For example, the maximum allowable temperature for insulation materials is usually between 90 ° C and 130 ° C, depending on the material grade.

Temperature stability:

The temperature of the equipment should remain stable during operation, and there should be no continuous rise or drastic fluctuations.

Safety margin:

The actual temperature should be kept below the maximum allowable temperature by a certain margin (such as 10 ° C to 20 ° C) to ensure safety.

 

relevant standards

The criteria for temperature rise testing vary depending on the industry and product type, and common standards include:

IEC 60950-1: Safety requirements for information technology equipment.

IEC 60601-1: Safety requirements for medical electrical equipment.

IEC 60335-1: Safety requirements for household and similar electrical appliances.

UL 60950-1: American standard, similar to IEC 60950-1.

 

Precautions

Sensor installation:

Ensure that the temperature sensor is securely installed to avoid looseness or detachment.

Environmental control:

The temperature of the testing environment should be stable to avoid external factors affecting the test results.

Load simulation:

The load conditions should be as close as possible to the actual usage situation to ensure accurate test results.

Multiple tests:

Conduct multiple tests on key areas and take the average as the final result.

 

Application field

Temperature rise testing is widely used in the following fields:

Electronic and electrical equipment: such as power supplies, transformers, motors, etc.

Household appliances: such as refrigerators, washing machines, air conditioners, etc.

Industrial equipment: such as frequency converters PLC、 Industrial controllers, etc.

Automotive electronics: such as car chargers, motor controllers, etc.

Through temperature rise testing, the temperature distribution of equipment under normal working conditions can be comprehensively evaluated to ensure its safety and reliability, providing important basis for product design, quality control, and market access.