图片名称

Solutions

Contact Us

图片名称
图片名称

National 24-hour service hotline

400-116-2629

Group Headquarters

Cell phone:18126505465

E-mail: webmaster@lcs-cert.com

Address: Shenzhen City, Baoan District, Shajing Street, Nga side of the school of Wei Juji Industrial Park, Building A 1 ~ 2 floor, Building C 3 floor

EU TPD Release Detection

 

The E-cigarette emission test report should include at least the release data of the following 24 substances generally:

 

 

No.

Test Item

Analyte

Test Standard

1

Nicotine emission consistency

Nicotine

AFNOR XP D90-300-3:2021 Annex A.3

2

Acetyl compound emission content

2,3-Butandione & 2,3-pentandione

AFNOR XP D90-300-3:2021 Annex A.4

3

Carbonyl compound emission content

Formaldehyde, acetaldehyde & acrolein

AFNOR XP D90-300-3:2021 Annex A.5

4

Specific element emission content

Antimony, nickel, cadmium, chromium, lead, arsenic & mercury

AFNOR XP D90-300-3:2021 Annex A.6

5

Alcohol compounds emission content

Ethylene glycol & diethylene glycol

CORESTA Recommended Method No. 84 - 2021

6

Tobacco-Specific Nitrosamines emission content

NNN, NNK, NAB & NAT

CORESTA Recommended Method No. 75 - 2022

7

Volatile organic compound emission content

Benzene, toluene, acrylonitrile,

1,3-butadiene & isoprene

CORESTA Recommended Method No. 70 - 2019

These substances have been determined based on research by the FDA and relevant public health agencies and may have negative effects on the health of users. The following are 24 common substances:

Formaldehyde

Acetaldehyde

Acrolein

Acetone

Propionaldehyde

Crotonaldehyde

2-butanone

Butyraldehyde

Benzene

Toluene

Ethylbenzene

M/p-Xylene

O-Xylene

Styrene

Isoprene

Acrylonitrile

1,3-Butadiene

Nickel

Lead

Chromium

Cadmium

Arsenic

Nicotine (Nicotine)

Tobacco specific nitrosamines (TSNAs, such as NNK, NNN, etc.)

 

Requirements for testing report:
Quantitative analysis: Specific release or content data for each substance needs to be provided, usually in micrograms (µ g) or nanograms (ng) per unit volume (such as per puff or per milliliter of smoke).

Detection method: Verified scientific methods such as gas chromatography-mass spectrometry (GC-MS) or high-performance liquid chromatography (HPLC) should be used for detection.

Repeatability: The test results should be reproducible, usually requiring multiple tests to ensure the accuracy of the data.

Comparative analysis: For new electronic cigarette products, it may be necessary to compare their emissions with traditional tobacco products (such as cigarettes) to assess their relative health risks.

 

Purpose:
These test data are an important component of PMTA (Pre Market Application), aimed at helping the FDA assess the impact of electronic cigarette products on public health. Through strict testing and disclosure requirements, the FDA aims to reduce the potential harm of electronic cigarette products to users, especially teenagers, and ensure that products on the market meet safety standards.

If electronic cigarette manufacturers fail to provide complete and accurate testing reports, their products may not pass the PMTA audit and therefore cannot be legally sold in the US market.

6 individual

Large-scale experimental base

150 individual

Professional Lab

30 All kinds of

Analysis Method

8 million times

Testing/year