UGR glare value test

The comparison evaluation between the brightness of the lamp directly to the eyes and the ambient brightness, rather than the absolute brightness of the lamp itself to the eyes.

 

UGR (Unified Glare Rating) is an indicator used to evaluate the degree of glare in indoor lighting environments, mainly focusing on the comparison between the brightness of the light directly entering the eyes and the brightness of the surrounding environment, rather than the absolute brightness of the light itself. The following is a detailed explanation of UGR values:

 

1. Definition of UGR
The UGR value evaluates the impact of glare on the human eye by quantifying the comparison between lamp brightness and ambient brightness. The lower the UGR value, the less glare and higher visual comfort.

 

2. Calculation formula for UGR

 

3. Rating criteria for UGR values
The range of UGR values is usually between 10 and 30, and the specific scoring criteria are as follows:

UGR<10: Almost glare free, suitable for high-precision visual tasks such as operating rooms and laboratories.

10 ≤ UGR<13: Slight glare, suitable for long-term workplaces such as offices and classrooms.

13 ≤ UGR<16: Acceptable glare, suitable for general indoor environments.

16 ≤ UGR<19: Obvious glare, may cause discomfort.

UGR ≥ 19: Strong glare, lighting design needs to be optimized.

 

4. Testing method for UGR value
Using a luminance meter: measure the brightness of the lamp in the direction of the observer's eyes (L) and the ambient brightness (Lb).

Calculate solid angle and position index: Calculate the solid angle (ω) and position index (p) based on the relative position between the lamp and the observer.

Substitute the measurement data into the UGR formula to calculate the glare rating.

 

5. Factors affecting UGR values
Lamp brightness: The higher the brightness of the lamp in the direction of the observer's eyes, the greater the UGR value.

Environmental brightness: The lower the background brightness, the higher the UGR value.

Number and location of lighting fixtures: The more lighting fixtures there are or the closer they are to the line of sight, the higher the UGR value.

Lamp shading design: A shading hood or diffuse reflection design can reduce the UGR value.

 

6. Methods to reduce UGR values
Choose low brightness lamps: Use lamps with lower brightness or diffuse reflection light sources.

Optimize the layout of lighting fixtures: avoid direct entry of lighting fixtures into the line of sight.

Increase ambient brightness: Increase background brightness and reduce brightness contrast.

Use a light shield or grille to reduce direct glare.

 

7. Application of UGR values
Indoor lighting design: helping designers optimize lighting schemes and improve visual comfort.

Standard compliance: Used to evaluate whether the lighting system complies with glare control standards (such as EN 12464-1).

Lamp selection: Choose lamps with low UGR values, suitable for long-term work places such as offices and classrooms.

By controlling the UGR value, glare in indoor lighting environments can be effectively reduced, improving visual comfort and work efficiency.