Travel conversion plug

Marking, size gauge inspection, anti electric shock protection, grounding resistance testing, fixed socket structure, plug and mobile socket structure, aging resistance and protection provided by switch housing (IP), insulation resistance and electrical strength, temperature rise, breaking capacity, normal operation, force required to unplug plug, flexible wire and its connection, mechanical strength, heat resistance (ball pressure), screws, current carrying parts and connections, creepage distance, electrical clearance and sealant penetration distance, insulation material's resistance to abnormal heat, flame resistance and electrical trace resistance, rust resistance, additional tests for plugs with insulation sheath

 

1. Travel conversion plug-in logo
Purpose: To ensure that the product has correct markings and identification, such as voltage, current, manufacturer information, etc., for users to use correctly.

Test content: Check whether the markings on the product are clear, durable, and comply with relevant standards.

 

2. Dimensional gauge inspection
Purpose: To ensure that the size of the plug and socket meets the standards and is compatible with other devices that meet the standards.

Test content: Use standard gauges to check whether the dimensions of plugs and sockets comply with regulations.

 

3. Anti electric shock protection
Purpose: To prevent users from accidentally coming into contact with live parts during use.

Test content: Check whether the design of plugs and sockets can effectively prevent fingers or other objects from coming into contact with live parts.

 

4. Grounding resistance test
Purpose: To ensure the effectiveness of the grounding system and prevent the risk of electric shock.

Test content: Measure the resistance of the grounding terminal to ensure it meets the standard requirements.

 

5. Fixed socket structure
Purpose: To ensure that the structural design of fixed sockets is reasonable and can be used safely and reliably.

Test content: Check the installation method of the socket, the strength of the fixing parts, etc.

 

6. Structure of plugs and mobile sockets
Purpose: To ensure that the structural design of plugs and mobile sockets is reasonable and can be used safely and reliably.

Test content: Check whether the shell and internal structure of the plug and mobile socket meet the standards.

 

7. Aging resistance and protection provided by switch housing (IP)
Purpose: To ensure that the product can maintain its protective performance after long-term use.

Test content: Evaluate the durability and protection capability of the product through aging testing and IP protection level testing.

 

8. Insulation resistance and electrical strength
Purpose: To ensure that the product has good insulation performance and can withstand a certain voltage without breakdown.

Test content: Measure insulation resistance and conduct high-voltage testing to ensure that the insulation material can withstand the specified voltage.

 

9. Temperature rise
Purpose: To ensure that the product does not pose a danger due to overheating during normal use.

Test content: Run the product at rated current and measure whether its temperature rise meets the standard.

 

10. Breaking capacity
Purpose: To ensure that switches or sockets can safely disconnect circuits.

Test content: Test the breaking capacity of switches or sockets at rated current and voltage.

 

11. Normal operation
Purpose: To ensure that the product can work reliably under normal usage conditions.

Test content: Simulate normal usage conditions, perform multiple plug and switch operations, and check the durability of the product.

 

12. The force required to unplug the plug
Purpose: To ensure that the plug will not easily come off during normal use and will not be difficult to remove.

Test content: Measure the force required to unplug the plug and ensure that it is within the specified range.

 

13. Flexible cords and their connections
Purpose: To ensure the safety and reliability of the flexible cord and its connecting parts.

Test content: Check whether the specifications, connection methods, and fixing methods of the flexible cords meet the standards.

 

14. Mechanical strength
Purpose: To ensure that the product can withstand certain mechanical stresses without damage.

Test content: Evaluate the mechanical strength of the product through impact, pressure, and other tests.

 

15. Heat resistance (ball pressure)
Purpose: To ensure that the product will not deform or be damaged in high temperature environments.

Test content: Press a ball pressure device of a specified weight onto the sample and evaluate its heat resistance at high temperatures.

 

16. Screws, current carrying components, and connections
Purpose: To ensure the reliability and safety of screws, current carrying components, and connections.

Test content: Check the tightness of screws, whether the material and connection method of current carrying components meet the standards.

 

17. Creepage distance, electrical clearance, and sealant penetration distance
Purpose: To ensure that the insulation distance between different potentials of the product is sufficient to prevent arcing or short circuits.

Test content: Measure the creepage distance, electrical clearance, and distance through the sealant to ensure compliance with standards.

 

18. Insulation materials' resistance to abnormal heat, flame, and electrical traces
Purpose: To ensure that insulation materials do not burn or produce electrical traces under abnormal thermal conditions.

Test content: Evaluate the flame resistance and electrical trace resistance of insulation materials through hot wire test, needle flame test, etc.

 

19. Rust prevention performance
Purpose: To ensure that metal components do not rust in humid environments.

Test content: Expose metal components to a humid environment to evaluate their rust prevention performance.

 

20. Additional test for pins with insulation sheath
Purpose: To ensure that the plug with insulation sheath can remain safe under normal use and abnormal conditions.

Test content: Conduct additional mechanical, electrical, and heat resistance tests to evaluate their safety.

 

summary
These testing projects cover multiple aspects such as safety, durability, mechanical performance, and electrical performance of electrical equipment, ensuring that the product can maintain safety and reliability under normal use and abnormal conditions. These tests are usually conducted according to international or national standards (such as IEC, UL, GB, etc.) to ensure that the product meets the safety requirements of the global market.

6 individual

Large-scale experimental base

150 individual

Professional Lab

30 All kinds of

Analysis Method

8 million times

Testing/year