Abnormal/abnormal state

Evaluate whether the product has caught fire, melted, emitted flammable gases, weakened insulation, etc. by short-circuit, open circuit components, and simulating various abnormal states in reality (such as rectification effect, cathode damage, double load)

Abnormal/abnormal state testing is an important part of electrical product safety assessment, aimed at simulating dangerous situations that may occur under fault or abnormal usage conditions, such as short circuits, open circuits, overloads, etc. Through this test, it is possible to evaluate whether the product may have safety hazards such as fire, melting, release of flammable gases, weakened insulation, etc., thereby ensuring the 

 

safety of the product in actual use. The following is a detailed explanation of abnormal/non normal state testing:

Test purpose
Evaluate product safety: Ensure that the product does not pose a threat to users or the environment in abnormal conditions.

Compliance with safety standards: Meet the requirements of international and domestic safety standards such as IEC 60950, IEC 62368, UL, etc.

Optimization design: Improve product design through test results to enhance its reliability and safety.

 

Common abnormalities/abnormal states
Short circuit:

Simulate a short circuit situation in the circuit and evaluate whether the product will experience overheating, fire, or insulation damage.

Open circuit:

Simulate the open circuit situation in the circuit and evaluate whether the product will have abnormal working conditions.

Overload:

Simulate the working condition of the equipment under rated load and evaluate whether overheating or damage will occur.

Rectification effect:

Simulate rectifier circuit faults and evaluate whether overheating or damage will occur.

Cathode damage:

Simulate damage to electronic components (such as capacitors and diodes) and evaluate whether it will cause fire or smoke.

Double load:

Simulate the working condition of the equipment under double rated load and evaluate its tolerance.

Cooling system failure:

Simulate the failure of the cooling system and evaluate whether the equipment will overheat or catch fire.

Power supply abnormality:

Simulate abnormal situations such as voltage fluctuations and reverse power connections to evaluate the equipment's tolerance.

 

test method
Short circuit test:

Artificially creating a short circuit in the circuit and observing whether the equipment will overheat, catch fire, or suffer insulation damage.

Use a thermal imaging device or temperature sensor to monitor temperature changes in the equipment.

Open circuit test:

Disconnect key components in the circuit and observe whether the equipment will have abnormal working conditions.

Overload test:

Increase the equipment load to 1.5 or 2 times the rated value, run continuously for a period of time, and observe whether the equipment will overheat or be damaged.

Rectification effect test:

Simulate rectifier circuit faults and observe whether overheating or damage will occur.

Cathodic damage test:

Artificially damaging electronic components (such as capacitors, diodes), observe whether it will cause fire or smoke.

Double load test:

Increase the device load to twice the rated value and observe its tolerance.

Cooling system failure test:

Turn off or damage the cooling system of the equipment, and observe whether the equipment will overheat or catch fire.

Power abnormality test:

Simulate abnormal situations such as voltage fluctuations and reverse power connections, and observe the equipment's tolerance.

 

Evaluation Criteria
Fire risk:

The equipment should not catch fire or generate flames during the testing process.

Melting risk:

The equipment casing or internal components should not melt or deform.

Combustible gases:

The equipment should not emit flammable gases or harmful smoke.

Insulation performance:

The insulation performance of the equipment should not be weakened and should still comply with safety standards.

Temperature variation:

The surface and internal temperature of the equipment should be within a safe range and should not exceed the limits specified by the standards.

 

test equipment
Power simulator: used to simulate abnormal situations such as voltage fluctuations and power reversal.

Load simulator: used to simulate overload or double load.

Thermal imaging device: used to monitor temperature changes in equipment.

Smoke detector: used to detect whether flammable gases or smoke are emitted.

Insulation tester: used to evaluate the insulation performance of equipment.

 

improvement measures
Add protection circuit:

Add overcurrent protection, overvoltage protection, temperature protection and other circuits in the design.

Optimize heat dissipation design:

Improve the cooling system to ensure that the equipment can effectively dissipate heat even in abnormal conditions.

Using high reliability components:

Choose components that are resistant to high temperatures and overloads to improve the equipment's tolerance.

User prompt:

Label safety tips on the device to remind users to avoid abnormal use.

summary
Abnormal/abnormal state testing is a critical step in ensuring the safety of electrical products. By simulating various faults and abnormal usage conditions, the safety performance of the product can be comprehensively evaluated, potential design defects can be identified, and improvement measures can be taken. This type of testing not only helps the product comply with safety standards, but also increases user trust and the product's market competitiveness.

6 individual

Large-scale experimental base

150 individual

Professional Lab

30 All kinds of

Analysis Method

8 million times

Testing/year