pressurization

Will permanent breakdown or flashover occur when testing the insulation between different parts of the sample to withstand the corresponding voltage values

 

Voltage withstand test (also known as high voltage test or dielectric strength test) is an important method for evaluating the insulation performance of electrical equipment, used to test whether the sample can withstand the specified voltage value between different parts without permanent breakdown or flashover. The following is a detailed explanation of the withstand voltage test:

 

1. Test purpose
Verify insulation strength: Ensure that the insulation material can withstand normal operating voltage and possible overvoltage.

Prevent breakdown or flashover: Avoid equipment damage or safety accidents caused by insulation failure.

Compliance with safety standards: Meet the requirements of relevant electrical safety standards.

 

2. Testing principle
Apply a test voltage higher than the operating voltage to different parts of the sample (such as between live parts and the casing, between different circuits) for a certain period of time.

Observe whether breakdown (permanent damage to insulation material) or flashover (surface discharge phenomenon) occurs.

Determine whether the insulation material meets the requirements based on the test results.

 

3. Testing equipment
Voltage tester: capable of outputting high voltage DC or AC voltage, usually with overcurrent protection function.

Test electrode: used to connect the high voltage terminal and ground terminal of the sample.

Safety protection devices: such as insulated gloves, insulated pads, etc., to ensure safe operation.

 

4. Testing steps
Preparation work:

Confirm that the sample is powered off and fully discharged.

Clean the surface of the sample to ensure that there are no contaminants such as dust, oil, etc.

Determine the test voltage and duration according to the testing standards.

Connection tester:

Connect the high voltage end of the voltage tester to the live parts of the sample.

Connect the grounding terminal of the tester to the non current carrying parts of the sample, such as the casing or grounding terminal.

 

Apply test voltage:

Slowly increase the voltage to the specified value (usually 1.5-2 times the rated voltage of the equipment).

Maintain the test voltage for a certain period of time (usually 1 minute).

Observation results:

During the testing process, observe whether breakdown or flashover occurs.

Record the leakage current value displayed by the tester (if any).

Judgment result:

If the sample does not experience breakdown or flashover and the leakage current is within the specified range, it is judged to be qualified.

If the sample experiences breakdown or flashover, it is judged as unqualified.

 

5. Testing standards
IEC 60335-1: Safety requirements for household and similar electrical appliances.

IEC 61010-1: Safety requirements for laboratory equipment.

GB 4706.1: Safety requirements for household and similar electrical appliances (Chinese standard).

UL 60950-1: Safety Standard for Information Technology Equipment.

 

6. Test parameters
Test voltage:

Determine based on the rated voltage of the equipment and testing standards.

For example, for equipment with a rated voltage of 230V, the test voltage may be 1500V (AC) or 2121V (DC).

Test time:

Usually 1 minute, the specific time depends on the standard requirements.

Leakage current limit:

According to the device type and standard, it is usually a few milliamps (mA).

 

7. Common problems and improvements
Breakdown or flashover:

Check whether the insulation material is aging, damaged, or contaminated, and replace it if necessary.

Increase the thickness of insulation materials or use materials with higher insulation levels.

Optimize design, increase electrical clearance and creepage distance.

Leakage current exceeds the standard:

Check the performance of insulation materials to ensure compliance with requirements.

Improve the working environment of equipment, reduce humidity and pollutants.

Optimize circuit design to reduce high-frequency leakage current.

 

8. Practical application
Household appliances, such as rice cookers and microwave ovens, require voltage withstand testing to ensure safety.

Industrial equipment such as motors, transformers, etc., withstand voltage testing is an important part of factory inspection.

Medical equipment: requires extremely high insulation performance and must comply with the IEC 60601-1 standard.

 

summary
Voltage withstand testing is an important means of evaluating the insulation performance of electrical equipment. By applying high voltage to detect whether the sample has breakdown or flashover, it ensures the safety and reliability of the equipment. During testing, attention should be paid to the testing voltage, time, and leakage current limit to ensure the accuracy and reliability of the test results.