Luminous flux test

Refers to the radiation power that can be perceived by the human eye, which is equal to the product of the radiation energy of a certain band per unit time and the relative visibility of that band. The unit of luminous flux is "lumens".

 

Luminous flux is a physical quantity that describes the total amount of visible light emitted by a light source, representing the radiation power perceived by the human eye. Its unit is lumens (lm). The following is a detailed explanation of the luminous flux test:

 

1. Definition of luminous flux

 

 

2. Unit of luminous flux
The unit of luminous flux is lumens (lm), defined as:

1 lumen (lm)=1 candela (cd) x 1 sphericity (sr).

 

3. Luminous flux testing method
Luminous flux testing usually uses an integrating sphere and a spectral radiometer, with the following steps:

Fixed light source: Install the light source at the center of the integrating sphere to ensure even distribution of light.

Measurement of spectral radiation flux: Use a spectral radiometer to measure the spectral radiation flux of the light source, Φ (∼) Φ e (λ).

Calculate luminous flux: Multiply and integrate the spectral radiation flux with the spectral luminous efficiency function to obtain luminous flux.

 

4. The role of the integrating sphere
Integral sphere is a device used to measure luminous flux, which is coated with high reflectivity material inside to evenly scatter light and ensure the accuracy of measurement results.

 

5. Application of luminous flux testing
Lighting Design: Help designers understand the total luminous output of light sources and optimize lighting solutions.

Lamp performance evaluation: Evaluate the luminous efficiency and luminous flux output of the lamp.

Standard compliance: used to verify whether the lighting fixtures comply with luminous flux standards (such as ENERGY STAR).

 

6. Factors affecting luminous flux
Light source type: Different light sources such as LED and halogen lamps have different luminous flux characteristics.

Light source power: The higher the power, the higher the luminous flux is usually.

Light source efficiency: The higher the light efficiency, the greater the luminous flux per unit power.

 

7. Relationship between luminous flux and lighting effect
High luminous flux: suitable for places that require high brightness, such as sports arenas and squares.

Low light flux: suitable for places that require soft lighting, such as bedrooms and dining rooms.

 

8. Precautions for luminous flux testing
Calibration equipment: The integrating sphere and spectral radiometer need to be calibrated before testing.

Environmental temperature: Temperature can affect the luminous flux output of the light source and should be tested at standard temperature.

Light source stability: During testing, it is necessary to ensure that the light source is in a stable working state.

Through luminous flux testing, the total amount of light emitted by the light source can be accurately understood, providing scientific basis for lighting design and lamp selection.