Alternating damp heat

This test is applicable to determine the adaptability of components, equipment, or other products to use, transport, and store under high humidity and temperature cycling conditions that typically result in condensation on the surface of the test sample. If this experiment is used to test the performance of packaged samples during transportation and storage, the test should be conducted together with the packaging.

 

Test purpose
Evaluate the adaptability of components, equipment, or other products under a combination of high humidity and temperature cycling conditions, and detect the potential performance degradation or failure of materials in humid and hot environments, especially the impact of surface condensation on the product.

 

Test Standard
According to the standard:

IEC 60068-2-30: Environmental testing - Part 2: Test methods Db (alternating humidity and heat)

GB/T 2423.4: Environmental Testing for Electrical and Electronic Products (Alternating Damp Heat)

MIL-STD-810: Environmental Engineering Considerations and Laboratory Testing

 

Test Principle
By simulating environments with high humidity and temperature cycling changes, evaluate the product's resistance performance under humid and hot conditions, especially the impact of condensation on the surface and internal structure of materials.

test equipment
Alternating Damp Heat Test Chamber

Temperature Recorder

Humidity recorder

Sample holder

Assessment tools (microscopes, electrical performance testers, etc.)

 

Test steps
Sample preparation:

Clean the surface of the sample to ensure that there are no oil stains or other contaminants.

Record the initial state of the sample (taking photos, conducting electrical performance tests, etc.).

If testing packaged samples, ensure that the packaging is intact and undamaged.

 

Test condition settings:

High temperature limit: set according to demand (usually+40 ℃ to+60 ℃).

Low temperature limit: set according to demand (usually+25 ℃ to+30 ℃).

Humidity range: Set according to demand (usually 90% -98% RH).

Temperature change rate: set according to demand (usually 1 ℃/min to 3 ℃/min).

Cycle times: Set according to demand (usually 10-50 times).

Residence time: Set according to requirements (usually 12 hours for high temperature and high humidity stages and 12 hours for low temperature and high humidity stages).

 

Test Run:

Start the test chamber and perform a wet heat cycle according to the set conditions.

Each cycle includes:

High temperature and high humidity stage: Heat up to the high temperature limit and maintain high humidity for 12 hours.

Low temperature and high humidity stage: Cool down to the low temperature limit and maintain high humidity for 12 hours.

Repeat the above cycle until the set number of times is completed.

Test completed:

Take out the sample and restore it to a standard environment for 24 hours.

Record the status of the sample after testing (taking photos, conducting electrical performance tests, etc.).

 

Result evaluation:

Appearance inspection:

Check the sample for corrosion, blistering, cracking, deformation, and other phenomena.

Electrical performance testing:

Evaluate the electrical performance changes of components (such as insulation resistance, dielectric strength, etc.).

 

Mechanical performance testing:

Evaluate the changes in properties such as tensile strength and impact strength of materials.

Microstructure analysis:

Observe surface microstructural changes using a microscope.

Packaging inspection (if applicable):

Check if the packaging is intact and if there is any water seepage or damage.

 

Precautions
Ensure the accuracy of temperature and humidity control in the test chamber and avoid deviations in testing conditions.

The sample should be placed evenly to avoid local overheating or excessive humidity.

After the test is completed, the sample needs to be restored to a standard environment before evaluation.

 

Test Record
Record the testing conditions (high temperature limit, low temperature limit, humidity range, temperature change rate, number of cycles, etc.).

Record the initial and post test states of the sample (taking photos, conducting electrical performance tests, etc.).

Record the specific manifestations of material performance changes.

 

Conclusion
Based on the test results, evaluate the product's tolerance performance in alternating humid and hot environments and issue a test report. Through this test, important basis can be provided for product design, material selection, and process improvement, ensuring the reliability of the product in humid and hot environments.