图片名称

Solutions

Contact Us

图片名称
图片名称

National 24-hour service hotline

400-116-2629

Group Headquarters

Cell phone:18126505465

E-mail: webmaster@lcs-cert.com

Address: Shenzhen City, Baoan District, Shajing Street, Nga side of the school of Wei Juji Industrial Park, Building A 1 ~ 2 floor, Building C 3 floor

Brightness (emergency sign)

Detect the brightness of the sample to determine if the minimum brightness, color uniformity/contrast are within an acceptable range

Brightness detection is an important testing method for evaluating whether emergency signs (such as safety exit signs, evacuation signs, etc.) can provide sufficient brightness and clear visibility in emergency situations. By measuring the brightness, color uniformity, and contrast of the sample, ensure that it meets relevant standards and requirements. The following is the detailed content of brightness detection:

 

1. Test purpose
Assess the minimum brightness of emergency signs to ensure they are clearly visible in emergency situations.

Check color uniformity and contrast to ensure the readability and consistency of the signage.

Verify whether the product complies with relevant safety standards (such as ISO, GB, EN, etc.).

 

2. Testing principle
Measure the brightness of emergency signs using a luminance meter or photometer to evaluate their visibility under different ambient light conditions. At the same time, check the color uniformity and contrast to ensure that the design of the signage meets the visual requirements of the human eye.

 

3. Testing methods
(1) Determine test parameters
Brightness range: Determine the minimum brightness according to standard requirements (such as ≥ 15 cd/m ²).

Measurement distance: determined based on actual usage (such as 1 meter, 2 meters, etc.).

Environmental light conditions: Simulate different environmental light conditions (such as full black, low light, high light) for testing.

(2) Measure brightness
Measure the surface brightness of emergency signs using a luminance meter or photometer.

Perform multi-point measurements at different positions (such as the center and edges) of the signboard to evaluate brightness uniformity.

Record the minimum brightness value to ensure it meets the standard requirements.

(3) Detect color uniformity
Use a colorimeter or spectral radiometer to measure the color coordinates (such as CIE x, y) of different positions on the indicator board.

Calculate color uniformity and evaluate color consistency.

(4) Detect contrast
Measure the background brightness (L_b) and pattern/text brightness (L_f) of the signage.

Calculate the contrast (C=L_f/L_b) to ensure it meets the standard requirements (e.g. C ≥ 5:1).

(5) Environmental light interference test
Measure the brightness of the indicator under different ambient light conditions (such as full black, low light, high light).

Assess the visibility and anti-interference ability of signage under different ambient lighting conditions.

 

4. Testing standards
International standards:

ISO 16069 (Safety signs and escape route indication systems).

ISO 3864 (Design Specification for Safety Signs and Colors).

Industry standards:

GB 13495 (Fire Safety Signs, China).

EN 1838 (Emergency Lighting and Sign Lights, Europe).

 

5. Testing equipment
Brightness meter: used to measure the brightness of indicator signs.

Colorimeter: used to measure color coordinates and uniformity.

Spectral radiometer: used for precise measurement of spectral distribution and color characteristics.

Environmental light simulation device: used to simulate different environmental light conditions.

 

6. Data analysis and evaluation
Minimum brightness: Ensure that the minimum brightness of the signboard meets the standard requirements (such as ≥ 15 cd/m ²).

Color Uniformity: Evaluate the color consistency at different positions of the signage.

Contrast: Ensure that the contrast between the pattern/text and the background meets the standard requirements (such as C ≥ 5:1).

Environmental light interference: Evaluate the visibility of signage under different ambient light conditions.

 

7. Common problems and solutions
Insufficient brightness: It may be due to aging of the light source or unreasonable design, requiring replacement of the light source or optimization of the design.

Uneven color: It may be due to uneven distribution of light sources or material issues, requiring adjustment of light source layout or replacement of materials.

Low contrast: It may be due to an inappropriate color combination between the pattern/text and the background, requiring a redesign of the color scheme.

 

8. Application scenarios
Fire safety: such as brightness detection of safety exit signs and evacuation signs.

Traffic signs: such as brightness detection of emergency lane signs and tunnel signs.

Industrial safety: such as brightness detection of emergency signs in factories and warehouses.

 

9. Test report
Testing conditions: including measurement distance, ambient light conditions, testing time, etc.

Test results: including minimum brightness, color uniformity, contrast, etc.

Conclusion and Suggestions: Evaluate whether the sample meets the relevant standards and propose improvement suggestions.

Through brightness detection, the visibility and readability of emergency signs can be comprehensively evaluated in emergency situations, ensuring that they can effectively guide personnel evacuation and ensure life safety in practical use.

6 individual

Large-scale experimental base

150 individual

Professional Lab

30 All kinds of

Analysis Method

8 million times

Testing/year