图片名称

Solutions

Contact Us

图片名称
图片名称

National 24-hour service hotline

400-116-2629

Group Headquarters

Cell phone:18126505465

E-mail: webmaster@lcs-cert.com

Address: Shenzhen City, Baoan District, Shajing Street, Nga side of the school of Wei Juji Industrial Park, Building A 1 ~ 2 floor, Building C 3 floor

ultraviolet radiation

Detect the effective ultraviolet radiation power of the sample

UV radiation detection is an important testing method for evaluating the effective UV radiation power of samples under UV irradiation. This type of testing is widely used in fields such as ultraviolet disinfection equipment, ultraviolet curing equipment, and ultraviolet aging testing to ensure the performance and safety of the equipment. The following is the detailed content of ultraviolet radiation detection:

 

1. Test purpose
Evaluate the effective ultraviolet radiation power of the sample under ultraviolet irradiation.

Ensure that the output power of the UV device meets the design requirements.

Verify the uniformity and stability of ultraviolet radiation.

 

2. Testing principle
The radiation power of a sample under ultraviolet light irradiation is measured by a UV radiometer or spectral radiometer, usually expressed in terms of radiation power per unit area (W/m ²) or radiation power per unit wavelength range (W/nm).

 

3. Testing methods
(1) Determine test parameters
Wavelength range: determined according to testing standards or equipment types (e.g. UVA: 315-400 nm, UVB: 280-315 nm, UVC: 100-280 nm).

Measurement distance: Determine the measurement distance based on actual usage (such as 10 cm, 20 cm, etc.).

Measurement time: Determine the measurement time according to the testing standards (such as 1 minute, 10 minutes, etc.).

(2) Measure UV radiation power
Measure the radiation power of the sample under ultraviolet light irradiation using a UV radiometer or spectral radiometer.

Ensure that the distance and angle between the measuring equipment and the sample meet the testing requirements.

Record the radiation power within different wavelength ranges.

(3) Evaluate radiation uniformity
Measure the ultraviolet radiation power at different positions of the sample and evaluate its uniformity.

Record the radiation power at each location and calculate the uniformity coefficient.

(4) Long term stability testing
Perform long-term ultraviolet irradiation on the sample and regularly measure the radiation power.

Evaluate the radiation power stability of the sample during long-term use.

 

4. Testing standards
International standards:

ISO 21348 (standard for measuring ultraviolet radiation).

IEC 62471 (Photobiological Safety Standard).

Industry standards:

GB/T 18830 (Performance Testing of Ultraviolet Disinfection Equipment).

ASTM G154 (Non Metallic Materials UV Exposure Test).

 

5. Testing equipment
UV radiometer: used to measure UV radiation power.

Spectral radiometer: used to measure the radiated power in different wavelength ranges.

Fixed device: used to fix samples and measuring equipment to ensure the stability of testing.

 

6. Data analysis and evaluation
Radiation power: Record the radiation power of the sample in different wavelength ranges and evaluate whether it meets the design requirements.

Uniformity coefficient: Calculate the radiation power uniformity of the sample at different positions and evaluate its radiation uniformity.

Stability: Evaluate the radiation power stability of the sample during long-term use.

 

7. Common problems and solutions
Insufficient radiation power: It may be due to aging or damage of the ultraviolet light source, and the light source needs to be replaced.

Uneven radiation: It may be due to an unreasonable layout of the light source, and the light source layout needs to be optimized.

Unstable radiation power: It may be due to unstable power supply or aging light source, and the power supply needs to be checked or the light source needs to be replaced.

 

8. Application scenarios
UV disinfection equipment: radiation power testing for UV sterilization lamps and UV water treatment equipment.

UV curing equipment: such as radiation power testing of UV curing lamps.

UV aging test: such as testing the aging performance of materials under UV irradiation.

 

9. Test report
Test conditions: including wavelength range, measurement distance, measurement time, etc.

Test results: including radiation power, uniformity coefficient, stability, etc.

Conclusion and Suggestions: Evaluate whether the sample meets the relevant standards and propose improvement suggestions.

Through UV radiation detection, the effective UV radiation power of the sample under UV irradiation can be comprehensively evaluated, ensuring its performance and safety in practical use.

6 individual

Large-scale experimental base

150 individual

Professional Lab

30 All kinds of

Analysis Method

8 million times

Testing/year