图片名称

The Australian plug and socket standard AS/NZS 3122:2017+A1:2021 will be enforced in November 2022. The AS/NZS 3122:2021 have published on 19 November 2021.There are some major changes have taken place in relevant standards. AS/NZS 3122:2015 will remain current for 12 months after the date of publication of this standard and after this time it will be superseded by AS/NZS 3122:2021.   Compared with the old version, the new version needs to pay special attention to the changes in Appendix A     ►►► Appendix J: Travel adaptors   A.2.1 The new definition of Travel adaptor adds the configuration of plugs and sockets to make the definition more clear Portable accessories constructed as a whole or in multiple parts, including parts of plugs or sockets in accordance with Figure 2.1 of AS/NZS 3112, and parts of plugs or sockets other than those in accordance with Figure 2.1 of AS/NZS 3112.   A.3.1 Socket portion requirements Parts of sockets that accept flat pin plugs in accordance with AS/NZS 3112 Figure 2.1 shall comply with the requirements of AS/NZS 3112, including all dimensional requirements. Parts of socket-outlets with a set of holes may accept plugs other than AS/NZS 3112, Figure 2.1, other types of plugs shall— (a) Complies with the requirements of AS/NZS 3112 except for dimensions; (b) Comply with the dimensional requirements of the corresponding national standards.   Socket parts with a set of holes that accept plugs conforming to BS 1363 require the addition of protective doors to the socket parts. As shown below:     The socket portion may incorporate multiple sets of apertures, however only two sets of apertures are accepted with connecting edges. That is, for an aperture group containing connecting edges, only connecting edges are allowed between the two live apertures, the two neutral apertures, and the two ground apertures (if present), see Figure A.1, (a) meets the requirements, (b) does not meet the requirements.     The real thing is as follows:     The connection hole group shall comply with the requirements of AS/NZS 3112, and the dimensions shall comply with the corresponding national standard requirements of the socket part, except for the connection area. The mobile adapter socket portion shall comply with the limitations of Section 4, items (e) and (f): (e) contains a plug portion with only two prongs and a socket for connecting a non-2-pin plug or a 2-conductor cord; (f) For each plug configuration that can be used with the adapter, contains a plug portion with a grounding prong and a socket without a grounding terminal or grounding contact. Note: The aperture group of clause A.3.1 accepts a variety of plug types.   A.3.2.3 Additional tests to remove alternative test methods from AS/NZS 60884.1     A.4 Plug portion removes alternative test method for AS/NZS 60884.1   A.5 Protection against live parts, A.6 Prohibited features, A.7 Marking of socket portions   A.8 Additional requirements for lower rated outputs   The socket portion of the travel adapter shall include the following warning if it can be inserted into a plug with a current rating greater than that marked on the socket section. The location may be on the packaging. WARNING - Devices with a current rating greater than that marked in the socket section cannot be used.   The travel adapter contains a hole set that accepts plugs rated below 220 V and should include the following warning. The location may be on the packaging. WARNING - Devices with a plug designed for 120 V must cover the 220 V or higher voltage range before they can be used with this travel adapter.   Other Australian Standards to be implemented:   standard release date excessive time Implementation time AS/NZS 3120:2021 2021.1 24个月 2023.1 AS/NZS 3123:2005+A1:2020 2020.7 24个月 2022.7 AS 3133-2020 2020.11 24个月 2022.11   If you have any other questions and learn more about testing and certification, please consult LCS specialists!

Tags

standard,the,of,with,as,nzs,socket,and,be,for

The transition period for KDB447498 can be extended until June 30, 2022, with the exception of PAG cases, the new version of the assessment will be mandatory after June 30. Notes for certification application: Transition period until June 30, 2022:     Attachment "447498 D04 Interim General RF Exposure Guidelines v01" is available for device authorization and must be used in conjunction with any other relevant revised KDB RF exposure procedures and policies, including FCC-TCB meeting presentations. The previous version, "447498 D01 General RF Exposure Guidance v06," may also be used during the transition period as long as a Form 731 and associated authorization application is filed with the FCC on or before June 30, 2022. "447498 D01 General RF Exposure Guidance v06" must be used in its entirety (ie, old and new procedures cannot be mixed when submitting an application for certification). After June 30, 2022, all applications can only use the new procedure that will be published as "D01 447498 General RF Exposure Guidance v07" and based on "447498 D04 Interim General RF Exposure Guidance", replacing the KDB "447498 General RF Exposure Guidance v06" ". The only exception is if the application for accreditation includes projects that are subject to the Pre-Approval Guidelines (PAG, KDB Publication 388624) submitted before July 1, 2022. In this case, the TCB can grant the device after the June deadline of March 30, 2022, with "447498 General RF Exposure Guidance v06" after PAG approval. If you have any other questions and learn more about testing and certification, please consult LCS specialists!

Tags

new,the,quot,rf,exposure,be,447498,general,and,june

The Australian plug and socket standard AS/NZS 3112:2017+A1:2021 will be enforced in June 2022.   新版本相比旧版本特别需要关注的是Appendix J的要求变化。 Appendix J: Integral or detachable plug portions of equipment for insertion into socket-outlets.   1. The general requirements of J 4.1 General test are modified as follows     For equipment with removable plug parts, the evaluation of Tests 2, 3, 5, 10 and 11 of Table J1 shall be carried out in the following two cases— (a) Assembly equipment for connecting removable plug parts; (b) The part of the removable plug after separation from the device.     2. J4.3 Mechanical Strength     J4.3.1 Barrel Test The first paragraph of the original sentence was deleted and changed to: The drum test is used to determine the mechanical strength of plug parts and equipment with integral or removable plug parts. For devices with removable plug parts, the removable plug part may come off during testing. If this happens, the removable plug portion should be reassembled with the device while the pins are straightened. Add at the end of this paragraph: Compliance is checked in accordance with the requirements of Section J4.3.3.   J4.3.2 Shock test (new requirement) Plug parts and equipment with integral plug parts or removable plug parts shall be able to withstand lateral impact forces. All samples subjected to the tests of Section J4.3.1 shall be tested as follows: (a) The sample shall be placed in the center of a steel plate with a thickness of at least 6 mm. The holes on the steel plate for the plug pins to pass through should conform to the corresponding socket standards. Clamp all the pins with clips to fix the sample on the steel plate; (b) Impact the specimen by any means with an impact energy of 1.0 ± 0.05 J using a spring impact test apparatus as described in Section 8.8.2 of AS/NZS 3100;     (c) Three shocks shall be applied at each point most likely to directly or indirectly stress the sealed joint of the specimen, and compliance shall be checked in accordance with J4.3.3.   J4.3.3 Specific Compliance Criteria (new requirement) This paragraph provides specific compliance criteria for passing tests of Sections J4.3.1 and J4.3.2. For devices with integral plug parts, the evaluation shall be performed on the integral device. For equipment with removable plug parts, the following shall be evaluated— (a) The removable plug portion is assembled with the device; (b) The part of the removable plug after separation from the device. After each test, the sample shall not show damage affecting safety, live parts shall not be exposed, and shall comply with the requirements of AS/NSZ 3100 Sections 5.1 and 5.2.2; After each test, internal conductive materials or conductive parts must not come off or loosen to avoid a hazardous situation. NOTE: Special care should be taken to separate any live parts from exposed metal parts or low voltage parts from extra low voltage parts.   J4.8.2 Detachable contact structure for equipment input current exceeding 0.2 A Delete the second paragraph and replace it with: Additional requirements for rewirable plugs: For connections intended for pins, contact should be made on two diametrically opposed surfaces unless a single spring assisted contact is used. Contacts should not be entirely dependent on the elasticity of the contact material and should have surfaces other than thermoplastic or elastomeric insulating materials. The positioning and contact characteristics of the contacts shall be independent of the terminal screws. The effectiveness of the contacts should be unaffected by the stress of any thermoplastic or elastic molding.   Applicable product categories: General power adapter       Power Adapter with Removable Plug Section:   USB charging head:     If you have any other questions and learn more about testing and certification, please consult LCS specialists!

Tags

standard,the,of,plug,be,with,parts,and,removable,for

< 1...798081...87 > proceed page
6 individual

Large-scale experimental base

150 individual

Professional Lab

30 All kinds of

Analysis Method

8 million times

Testing/year