图片名称

Draft Technical Regulations on Minimum Energy Efficiency Standards for Peruvian Lighting Products (MEPS)

Author.

LCS

Source:

Post time:

2026-09-20

Regarding the Minimum Energy Efficiency Standard (MEPS) for lighting products, the Peruvian Ministry of Energy and Mines (MINEM) issued Ministerial Resolution No. 290-2026-MINEM/DM on July 22, 2026.

 


 


 

1、 Scope of application of regulations

For indoor general lighting sources, there are six categories:


 

1. Incandescent lamp: power 25-200W, voltage ≤ 250V, A/PS lamp type, transparent/frosted/white glass, E27 lamp head;

2. Single/double ended fluorescent lamps, equipped with external ballasts;

3. Compact fluorescent lamp CFL: power ≤ 80W, voltage ≤ 250V, E27 threaded lamp head;

4. LED bulb: luminous flux 60-3300lm, AC input 50-480Vac, 50/60Hz; Lamp heads E10/E11/E12/E14/E17/E26/E27/GU10/GZ10, including products that can be adapted to the above lamp heads through passive adapters; Simultaneously limiting the range of white light chromaticity coordinates;

5. Double ended linear LED tube: luminous flux>400lm, lamp head G5/G13/Fa6/Fa8/R17d, can be directly driven or use existing electromagnetic ballasts;

6. LED embedded/surface mounted downlight: circular/square maximum 30cm, power ≤ 25W, AC 50-480Vac, 50/60Hz.


 

Exempted products (not subject to this regulation)


 

1. Luminous flux>6500lm or<30lm;

2. Battery powered, non grid connected lighting;

3. Special uses: insect killing lamps, medical, scientific research, ultraviolet/infrared lamps, black light lamps, transportation, mining, plant growth, aquarium, signal lights, projection, stage;

4. Adjustable color light source CTLS (note: adjustable color temperature white light TWL is not excluded and still needs to comply with regulations).


 


 


 

2、 Core technical requirement: Minimum luminous efficiency of MEPS (lm/W)

Phase 1 (effective immediately), Phase 2 (12 months after effective, stricter)

Effective rules: The law will officially come into effect 12 months after its publication in the official newspaper El Peruano; Implement energy efficiency limits in two stages: the first stage (Fase1) will be launched in the 12th month, and the second stage (Fase2) will be launched 24 months after its release