图片名称

FCC releases KDB 775926 D01: SAR testing standards for alien wireless devices undergo significant adjustments

Author.

LCS

Source:

Post time:

2026-06-11

 

On May 29, 2026, the FCC officially released SAR testing guidelines (KDB 775926 D01) for irregular shaped wireless devices such as smart wearables, neck hanging terminals, etc. On the basis of the preliminary draft for soliciting opinions, this document clearly specifies the definition of testing locations, measurement spacing, and antenna testing strategies.

 

Interpretation of Key Technical Changes:

 


 

Accurate definition of testing location:

Body worn items (pockets/neck hooks): A 1g body SAR test is required.

 

Head wearing accessories (glasses/goggles): Emphasize the positioning accuracy on the simulation body, requiring the emission source to maintain the minimum distance from the surface of the simulation body to ensure the rigor of the test.
 


 

Optimization of measurement boundary conditions:

According to the IEC/IEEE 62209-1528:2020 standard, the distance between the measurement area and the side wall is required to be adjusted to 20mm. This change corrects the previous broad requirement of 3-5cm in KDB 865664 D01, improving the flexibility and accuracy of testing.

 


 

Testing strategy for irregular structured antennas:

For antennas with raised areas, the new regulations provide two simplified testing paths: one is to tilt the equipment to test the edges separately; The second is to align the protruding part with the center of the simulated body for rapid scanning.

 

Judgment logic: If the preliminary scan result is below 0.8 W/kg, only the worst edge needs to be tested; If it exceeds the threshold, complete testing must be conducted on both edges.