Information | Cabinet Power Socket PDU

Author.

LCS

Source:

Post time:

2026-04-20

 

The cabinet PDU, as the most tightly distributed component at the end of the data center room, is dedicated to the basic power supply and distribution and special protection needs of multiple equipment in the cabinet. PDU, The full name is Power Distribution Unit, which distributes the output current from UPS to the end distribution equipment of various IT devices. It is a key equipment that connects power supply infrastructure and IT systems, and connects the normal operation of equipment in the computer room. Its stability and safety are directly related to the electrical safety of IT equipment and even the entire computer room.

 

PART.1

material

(1) PDU shell: PDU is generally made of high-strength, high-quality, thickened aluminum alloy profiles or black cold-rolled steel plates, which are much higher than industrial profile standards, with compressive and corrosion resistance. The surface is treated with anodizing and spraying, and the overall strength is high, sturdy and durable.

 

(2) Component module: The cabinet PDU product output module components, functional modules, and control modules are all made of high flame retardant alloy devices, with flame retardant performance reaching the UL94 V-0 international standard. They have excellent wear resistance, impact resistance, moisture resistance, and high insulation performance, which can effectively prevent electric shock hazards during use.
 

 

(3) Connector material: The cabinet PDU socket plug group is made of high-quality, high hardness tin phosphorus bronze material, which has good conductivity, elasticity, wear resistance, and diamagnetism, meeting the requirements of reliable plugging and unplugging, and preventing virtual connection and sparking.


 

 

PART.2

Input part

(1) Plug: The cabinet PDU has self wiring, wiring terminals, and national standards IEC-C13/C19、 British standard, American standard, and industrial connector inputs, as well as input plugs, must have safety certifications such as UL/CCC/VDE/CE.



 

(2) Cable: According to different power consumption schemes, different specifications of safety rubber sheathed cables are matched. The cabinet PDU cables have CCC/UL/CE/VDE and other standard certifications, such as 10A using 3 * 1.5mm ² wiring; 16A matching wire diameter 1.5-2.51.5mm ²; 32A matching wire diameter 4.0-6.0mm ²; The supporting wire diameter of 63A is 6.0-10.0mm ².


 

PART.3

Output section

Provide standard output and IEC output units from various countries around the world according to different power consumption requirements, to meet the power needs of various equipment and instruments.

 


 

PART.4

functional module

The cabinet PDU socket can be equipped with various functional modules such as power indication, filtering protection, intelligent digital display, overload protection, air switch module, junction box, USB module, timing module, main/sub control switch, lightning surge protection, double break and double disconnect protection, USB module, RJ45 module, WIFI router, etc., to ensure product safety and reliability.



 

PART.5

Installation features

Installation performance: The cabinet PDU adopts a standardized design of 19 inches, supporting horizontal installation (standard 19 inches) and vertical installation (parallel installation with the cabinet column). Installation is very simple, requiring at least 2 screws to firmly fix the PDU.