Compatibility requirements and examples of ultra-low voltage connectors in lighting appliances

Author.

LCS

Source:

Post time:

2026-04-13

The combination between LED power supply and LED lighting fixtures usually uses a connector, namely a Safety Extra Low Voltage (SELV) connector. There are special requirements for ultra-low voltage connectors in Chapter 5 of the standard IEC 60598-1:2024 "Luminaires Part 1: General Requirements and Tests".

 

In the product design process, for the SELV circuit part, manufacturers usually believe that the safety extra low voltage will not cause electric shock injury, and ignore the safety considerations in terms of structure. This may result in significant non-compliance issues with the low-voltage connector structure during the certification process.

 

Standard original text:

 

The standard IEC 60598-1:2024 requires that the low-voltage connector system of SELV shall not have unsafe compatibility with couplers in Class I and Class II luminaires that comply with the IEC 60320 "Household and Similar Use Appliances" series standards, as well as with plugs or sockets in the main power supply systems of various countries. It also specifies the testing method and schematic diagram for testing the unsafe compatibility between the SELV low-voltage connector system and the main power plug or socket (as shown below).

 

Common examples and analysis of unsafe compatibility:

1. The low-voltage connector used for Class III lamps (see Figure 1) shall not have any possibility of electrical contact with plugs, sockets, and couplers used in the mains voltage system. For example, couplers that comply with the IEC 60320 standard, regardless of whether they meet the specified standard specifications, must not have unsafe compatibility with SELV low-voltage connectors. This type of unsafe compatibility manifests in two situations: single pin contact or dual pin simultaneous contact. Figure 2 shows an example of an unsafe compatibility situation where single pins are in contact. At this time, there is electrical contact between the single pin of the Class II mains coupler and the Class III low-voltage connector. This unsafe compatibility may result in the user directly touching the neutral wire of the mains. The exposed pin in Figure 2 can be directly contacted. If the load is a filament light source, the pin may be one pole of the mains power, posing a high risk of electric shock.

 

There is an unsafe compatibility situation where both pins have electrical contact at the same time. The specific example is that the dual pins of the low-voltage connector in Figure 2 can be simultaneously inserted into the female plug of the mains coupler. This situation may result in a high risk of electric shock at the end of Class III lamps. Class III lamps do not have particularly strict requirements for the design of anti electric shock structures. The current carrying parts and accessible surfaces only need basic insulation or no insulation. Unlike Class II lamps, there is a need for strengthened insulation or double insulation between live parts and accessible surfaces.

 

2. There are also unsafe and safe compatibility issues between Class III ultra-low voltage connectors with single cylindrical positive and negative poles and commercial power sockets. Accept the corresponding size of Class III ultra-low voltage connectors according to the principles of the cause analysis column in Table 1.

 

Table 1 Types of Low Voltage Connectors and Analysis of Acceptable Reasons

The above dimensions refer to the compatibility of German sockets, and there may be differences in other countries and regions.

 
 

 

Corresponding CTL resolution:

 

 

With the popularity of detachable LED light sources, the use of low-voltage connectors in lighting products and lighting controller products is increasing. The unsafe compatibility between ultra-low voltage connectors and couplers and sockets in the main power system has always been a major structural safety issue in lighting products. To design a low-voltage connector that meets standard requirements, it is necessary to integrate the standard requirements into the product design of the connector to avoid design defects.