图片名称

Analysis of VW80000 E-21: Why does the pin voltage have to drop in seconds after power failure?

Author.

LCS

Source:

Post time:

2026-04-02

In the VW80000 electrical performance specification, the E-21 Backfeeds test is a very "covert but deadly" project. This test is to ensure that automotive electronic components will not "reverse" voltage from the device to these ports after certain input terminals are powered off. Simply put, when power is not supplied to this pin, it not only runs out of power on its own, but also cannot drain electricity from other parts of the device.

 

01 Test Purpose

 

Ensure circuit independence: Verify that the various switch control terminals of the tested device (such as t.15 ignition signal, t.87 relay output, etc.) are independent of each other.

 

Backfeed prevention: When a control signal of the device (such as the ignition switch) is disconnected, the device may still be connected to constant power (t.30) internally. If not isolated, constant power may "leak" back to the ignition switch pin through the internal circuit, causing abnormal vehicle circuits.

 

02 Testing principle and circuit diagram

 

t. 30 (Constant Power): The line directly connected to the DUT at the top of the diagram indicates that the battery is always on and connected during the testing process. This is a potential source of leakage.

t. 31 (Grounding): The line at the bottom of the diagram is connected through switch S2.

K (tested terminal): The terminal connected through switch S1 in the middle, which is the object we want to test (such as ACC or IGN input pin).

Measurement point (V): The voltmeter/oscilloscope is connected in parallel between terminal K and ground to monitor the voltage change on terminal K at the moment S1 is disconnected.

 

03 Test conditions

 

The test needs to be conducted at full load operation (Operamax), high voltage (Vopmax -0.2V), and different temperatures of the equipment.

 

It is mainly divided into two test cases:

 

Test case 1 (disconnected input, normal grounding):

R (load resistance): Not connected.

S1 (input switch): Open - analog cut-off signal.

S2 (Grounding switch): Closed - Grounding is normal.

Purpose: This is a rigorous static voltage test, and since R does not exist, the measurement point K is in a suspended state.

In this state, if even a very small current of μ A level leaks from t.30 to the K terminal inside the DUT, the voltage V will rapidly increase because there is no pull-down resistor R to discharge the power.

 

Test case 2 (Disconnect input and ground):

R (load resistance): Connect a resistor with a resistance of ≥ 10k Ω.

S1 (input switch): disconnected.

S2 (grounding switch): disconnected.

Purpose: To simulate situations of poor or lost grounding. Sometimes when the ground wire is disconnected, the current will try to find other paths to flow out (such as reverse flow through the input pin). If the circuit design is improper, the current will flow through the K terminal and the external 10k Ω resistor to the ground. This test is to prevent this situation.

 

04 Qualification Standards

 

Voltage drop speed: Within 20 milliseconds after the switch is turned off, the voltage on the tested terminal must drop below 1V.

 

Voltage curve shape: Observing the oscilloscope curve, the descent process must be smooth downward. If there is any upward protrusion (positive pulse) in the middle, it indicates that a reverse induced electromotive force is generated during the internal circuit switching, which is also not allowed.

 

05 New energy vehicles still need to undergo E-21 testing

 

The 12V low-voltage architecture still exists:

Whether it is the ID.4, ID.6 (MEB platform) or Audi e-tron (PP platform), although they have high-voltage batteries, all ECUs, sensors, and actuators are still powered and controlled by the 12V system.

t. 30 (normal live wire) is still directly connected to the 12V battery.

t. Although the ignition signal is more controlled by gateways or body controllers through electronic switches in new energy vehicles, the physical power on/off logic remains unchanged.

 

Functional safety requirements:

In new energy vehicles, many signals are logically related. If the internal components of the vehicle experience reverse power feeding, causing the t.15 signal line to remain at an abnormal voltage, the central control unit of the vehicle may make a misjudgment, thinking that the vehicle is still in the "ignition" or "standby" state. This may result in false alarms for anti-theft alarms, errors in the airbag controller, and even affect the handshake logic of the charging station (some charging logic requires determining whether the vehicle has completely shut down).

 

06 Meaning

 

This test is to prevent backflow in the automotive electronic system. For example, if you turn off the car light switch, but due to an internal design defect in the module, the constant electricity flows back into the switch circuit, causing the car light to light up slightly or the system to misjudge the switch status. The E-21 test is designed to eliminate this hardware design hazard.